CARE & CLEANING
DESCALE (dESc)
NOTE
Even if you used the provided water
filter, we recommend you to descale if
there is scale build-up in the water tank.
Only descale via the descale menu.
1 – Prepare for Descale
Empty the drip tray and insert into
a)
position.
Turn the machine off and allow to cool for
b)
at least 4 hours. With the machine off, press
and hold the 1 CUP button, then press and
hold the POWER button together for
3 seconds. rSEt will appear on the LCD.
THEN PRESS
& HOLD
Rotate SELECT dial until 'dESC" appears
c)
on LCD and press the dial to confirm.
SELECT
SELECT
SELECT
TEMP TEXTURE
TEMP TEXTURE
TEMP TEXTURE
34
2 – Empty Boilers
a)
b)
c)
POWER
When the water is completely empty, close
the valve by rotating screws clock-wise until
seated. Do not overtighten screws to avoid
damages to the valves.
SELECT
SELECT
SELECT
TEMP TEXTURE
TEMP TEXTURE
TEMP TEXTURE
Remove the grey silicone cover on the
lower front panel marked DESCALE
ACCESS.
REMOVE
Place a cloth over the drip tray to prevent
steam escaping.
Use a flat head screw driver to rotate the
right valve counter-clockwise SLOWLY
until fully open. As the valve opens, steam
may be released.
NOTE
If there's no water released into the drip
tray, press and hold the 1 CUP button for
3 seconds. This will release water from
the boiler.