Leister Technologies AG

6 Service menu

Caution: Service menu requires the tool to be connected to line/mains voltage!
Service menu enables altering of temperature unit, nominal voltage and maximum tempera-
ture adjustment as well as reset of the announcement "Service recommended". In addition
the service menu offers a readout of operating hours, number of switching on cycles and er-
ror memory.
After entering service code the specific menu items can be selected by turning e-Drive con-
trol button clock- (cw) or counterclockwise (ccw). Display and setting options will be de-
scribed in the following chapters.
V3.xx
Start
Enter service code
Temperature unit
Rated voltage
Reset «Service
recommended»
Hours of operation
Number of switch-on
cycles
 No heating output as long as Ghibli AW is in the service mode menu
 Numbers of more than 4 digits are displayed as scrolling text
 Quit service menu by disconnecting tool from the line/mains voltage only (unplug the tool)
Repair instructions
Ghibli AW
Revision: B
Number temperature
limit switch-off cycles
Temperature
adjustment
Error memory 0
Error memory 1
Error memory 4
QM
Page
Created
Released
Modified
Select the specific menu items
clockwise by turning e-Drive
control button clockwise
Select the specific menu items
counterclockwise by turning
e-Drive control button
counterclockwise
INN_FO_29
9 / 48
13.04.15 PRI
20.04.15 PRI
02.07.18 PRI

Advertisement

Table of Contents
loading

This manual is also suitable for:

1411191700

Table of Contents