Leister Technologies AG
14.3 Maximum temperature adjustment (optional)
Note: This chapter describes the possibility to do a maximum temperature adjustment. This
procedure is optional!
Keep test setup unchanged during entire adjusting procedure if possible! Reasonably per-
form just a broad adjustment, because the test setup in itself has a wide tolerance.
1. Maximum temperature is determined as described in the function check (chapter 14.2)
external thermocouple into center of tubular nozzle ø 5/8mm, temperature setting
620°C (1150°F), air flow setting step 5, temperature measurement after 5 minutes
2. If measured temperature deviates essentially from indicated temperature, the maximum
temperature may be adjusted within the range of -20°C..+10°C (-36°F..+18°F); service
menu (chapter 6.9)
3. Verify new maximum temperature (item 1) and iterate adjusting procedure (item 2) if
necessary
14.4 Checking completeness
Check printed details on the nameplate: Type, voltage, current, power consumption
(must correspond with the above measurements!)
Check serial number (yymmdd0000) and production code (yyww)
Company label LEISTER must be neatly printed on the handle
Check power supply cord mechanically and electrically (correct plug type for country,
conductor cross-section as per rated current)
Both air filters must be fitted
All screws must be tightened
Check for cleanliness and possible damage
Shake tool: Heating element may not hit heater tube (otherwise mica tube is missing)
Repair instructions
Ghibli AW
Revision: B
yy:
year of production
mm: month of production
dd:
day of production
0000: consecutive number
QM
INN_FO_29
Page
44 / 48
Created
13.04.15 PRI
Released
20.04.15 PRI
Modified
02.07.18 PRI
yy:
year of production
ww: week of production