Leister Technologies AG
9.3 Heating element
Check ceramic parts for mechanical damages and overheating indications
If heating channels are clogged, try to clear them by using compressed air
Check heating element type and resistance
Replace the heating element if it is either mechanically damaged or if any heating channels
are clogged. If type or resistance are incorrect replace heating element as well.
Note
Tool must successfully pass test procedure after tool assembling (chapter 14)
Repair instructions
Ghibli AW
Revision: B
Open tool according to chapter 8.1
Check heating element for mechanical damage and
clogged heating channels
Check resistance of heating element by using an
ohmmeter
Voltag
[V]
L1
100
L2
N
120
230
Reassemble tool in reverse order, terminate as-
sembling according to chapter 8.2
Visual inspection, compressed air, multimeter
Power
Resistance
[W]
L1 N
1450
ca. 13.0
1700
ca. 15.6
2200
ca. 45.5
QM
INN_FO_29
Page
25 / 48
Created
13.04.15 PRI
Released
20.04.15 PRI
Modified
02.07.18 PRI
Multimeter
Resistance
[Ω]
[Ω]
L2 N
ca. 13.0
ca. 15.6
ca. 45.5