Nominal Voltage - Leister GHIBLI AW Repair Instructions

Hot air tool
Hide thumbs Also See for GHIBLI AW:
Table of Contents

Advertisement

Leister Technologies AG

6.4 Nominal voltage

Ghibli AW enables nominal voltage selection. The service menu offers nominal voltages of
100V, 120V and 230V. Nominal voltage input defines the limits for under- and overvoltage
announcements from line/mains voltage.
or
or
or
Repair instructions
or
or
or
or
Ghibli AW
Revision: B
Menu item "Nominal voltage" indicates the
currently selected nominal voltage
Push e-Drive control button shortly to alter
the nominal voltage
Displayed nominal voltage flashes
Select requested nominal voltage according
to rated voltage on the nameplate by turning
e-Drive control button
 clockwise
counterclockwise
Quit menu item:
 Save nominal voltage selection by push-
ing e-Drive control button for a long time
 Not save nominal voltage selection by
pushing e-Drive control button shortly
Then menu item "Nominal voltage" indicates
the currently selected nominal voltage again
QM
INN_FO_29
Page
12 / 48
Created
13.04.15 PRI
Released
20.04.15 PRI
Modified
02.07.18 PRI
increase voltage
decrease voltage

Advertisement

Table of Contents
loading

This manual is also suitable for:

1411191700

Table of Contents