ZT‐20xx‐IOG SERIES 
1
What's in the Shipping Package?
The shipping package contains the following items:
ZT‐20xx‐IOG Module 
If any of these items are missing or damaged, please contact your local
distributor for more information. Save the shipping materials and cartons in
2
Preparing the Device 
1. Power Supply: +10 ~ +30 V
+Vs
GND
2.
"ZT-2000 Configuration Utility"
Install
http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/utility/
-
- CD: \\Napdos\ZigBee\ZT_Series\Utility
ICP DAS, ZT‐20xx‐IOG SERIES Quick Start, Version 1.0.0
Copyright 
case you need to ship the module in the future.
DC
©
 2016 by ICP DAS Co., Ltd. All Rights Reserved. 
ANT‐124‐05 
+Vs
GND
to configure the ZT-20xx-IOG device.
Quick Start
Quick Start 
   Page 1 
 
 
 

Advertisement

loading

Summary of Contents for ICP DAS USA ZT-20 IOG Series

  • Page 1 ZT‐20xx‐IOG SERIES  Quick Start   What’s in the Shipping Package? The shipping package contains the following items: ZT‐20xx‐IOG Module  ANT‐124‐05  Quick Start    If any of these items are missing or damaged, please contact your local distributor for more information. Save the shipping materials and cartons in case you need to ship the module in the future.  ...
  • Page 2  Hardware Basic Setting  1. Hardware Setting Interface   ZT-2043-IOG  ZT-2053-IOG  ZT-2055-IOG  9 10 11 12 RF Channel Node ID Reserved ZT-2060-IOG    Basic Setting Parameters for Hardware   ① DIP 1 : Module Initial Mode  For normal operation, set the DIP_1 to the RUN position. ...
  • Page 3 ② DIP 2 : DI Event trigger mode or way The event trigger modes of the ZT-IOG system, the same are the trigger ways for the DI channel of the ZT-IOG module. Users is able to choose the suitable mode via refering user manual for detail descriptions.
  • Page 4 Node ID DIP_4 DIP_5 DIP_6 DIP_7 DIP_8 Node ID DIP_4 DIP_5 DIP_6 DIP_7 DIP_8 0x0000 0x0010 0x0001 0x0011 0x0002 0x0012 0x0003 0x0013 0x0004 0x0014 0x0005 0x0015 0x0006 0x0016 0x0007 0x0017 0x0008 0x0018 0x0009 0x0019 0x000A 0x001A 0x000B 0x001B 0x000C 0x001C 0x000D 0x001D 0x000E...
  • Page 5  Software Advanced Setting  1. Advanced Setting Parameters for Software The following items are the main functions and configurations to the software advanced setting, please refer the user manual for more information. http://ftp.icpdas.com.tw/pub/cd/usbcd/napdos/zigbee/zt_series/document/zt-iog/ Disconnection Detection : Safe Value (Router), Check-Router-Alive (Coordinator) I/O Channel Pair Relationship : Channel Offset (DI/DO) Other Parameters : Pan ID, RF Power, Refresh Interval...
  • Page 6 can call the software utility. Execute the ZT-20xx-IOG Configuration Utility (Windows Based): ⑤ Use “ZT-IOG Series Configuration Utility” to connect the ZT-20xx-IOG. ⑥ a. Click【COM Port Setting】to select the COM port of the ZigBee converter. b. Click【Read Setting】to read the current settings of the ZT-20xx-IOG module. After reading the settings, directly set the parameters in “New”...
  • Page 7: Wiring Connection

     Wiring Connection    Model Input Type ON State Readback as 1 OFF State Readback as 0 Relay ON Relay OFF Dry Contact Voltage > 3.5 V Voltage < 1 V Wet Contact (Source) Open Collector ON Open Collector OFF Wet Contact (Sink) Close to GND Open...
  • Page 8: Troubleshooting

    Output   Model ON State Readback as 1 OFF State Readback as 0 Type Drive Relay     Resistance Load     Resistance Load Inductive Load Relay Output Troubleshooting If you have any difficulties using your ZT-20xx-IOG series I/O device, please send the following contents of the problem to service@icpdas.com Description of the problem...