② DIP 2 : DI Event trigger mode or way
The event trigger modes of the ZT-IOG system, the same are the trigger ways for
the DI channel of the ZT-IOG module. Users is able to choose the suitable mode
via refering user manual for detail descriptions.
Trigger Mode DIP_2
Level Mode
Pulse Mode
③ DIP 3 : Encryption
In wireless communication, it provides data encryption that supports AES-128 bit
encryption algorithm. This setting is based on the ZigBee Coordinator, other
ZT-IOG modules within the same group are synchronized passively.
Encryption DIP_3
Disable
OFF
Enable
ON
④ DIP 4~8 : Node ID
The Node ID is the ZigBee device ID, or known as the node addresses.
 The settable range is 0x0000 ~ 0x001F, up to 32 groups, cannot duplicate in
the same group
 A ZT-IOG network must specify a device to 0x0000 (ZigBee Coordinator)
 The ZigBee Coordinator must be supplied power permanently, or the IOG
system cannot work properly.
ICP DAS, ZT‐20xx‐IOG SERIES Quick Start, Version 1.0.0
Copyright 
Descriptions
If any DI channel state is high, all DO channel states are high.
OFF
If all DI channel states are low, all DO channel states are low.
If any DI channel is triggered to rising edge, all DO channels will
ON
change to the reverse edge once.
Descriptions
Not using encryption
Using AES-128 bit encryption for wireless communications
©
 2016 by ICP DAS Co., Ltd. All Rights Reserved. 