Part 9: Electrical Connection; Connection Of The Hob - Philco PHD 61FS Owner's Manual

Induction glass-ceramic hob
Table of Contents

Advertisement

PART 9: ELECTRICAL CONNECTION

·
The installation of this appliance and the connection to the electrical network should be entrusted only
to an electrician perfectly to the fact of the normative regulations and which respects them scrupulously.
·
Protection against the parts under tension must be ensured after the building-in.
·
The data of connection necessary are on the stickers place on the hob casing near the connection box.
·
The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking
device with a contact opening of at least 3 mm.
·
The electrical circuit must be separated from the network by adapted devices, for example: circuit
breakers, fuses or contactors.
·
If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated in the
fixed installation, in accordance with the installation regulations.
·
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or even.
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
Mains
230V~ 50/60Hz
400V~ 50/60Hz
*
Calculated with the simultaneous factor following the standard EN 60 335-2-6.

Connection of the hob

Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase
230V~1P+N
Put a bridge between terminal 1 and 2.
Attach the earth to the terminal "earth", the neutral N to terminal 4, the Phase L to one of the terminals 1 or 2.
Biphase
400V~2P+N
Attach the earth to the terminal "earth", the neutral N to 4, the Phase L1 to the terminals 1 and the Phase L2 to
the terminal 2.
Caution! Frequent loosening and screwing of the screws on the connection box risks damaging the
efficiency of the tightness once screwed. It is therefore advisable to keep screwing and unscrewing to a
minimum. Ensure that the cables are correctly inserted and tightly screwed down.
We cannot be held responsible for any incident resulting from incorrect connection or which could arise
from the use of an appliance which has not been earthed or has been equipped with a faulty earth
connection.
EN - 18
Copyright © 2019, Fast ČR, a. s.
Connection
Cable diameter
1 Phase + N
3 x 2,5 mm²
2 Phases + N
4 x 1.5 mm²
Cable
Protection calibre
H 05 VV - F
H 05 RR - F
H 05 VV - F
H 05 RR - F
25 A *
16 A *
Revision 08/2019