Capacitor Charge Lights - Komatsu 830E-1AC Operation & Maintenance Manual

Sound attenuation package
Hide thumbs Also See for 830E-1AC:
Table of Contents

Advertisement

OM2049 2/13

CAPACITOR CHARGE LIGHTS

Observe both capacitor charge lights (CCL1, CCL2).
CCL1 is on the outside of the contactor box. CCL2 is
on the switch panel inside the low voltage area. The
lights will stay illuminated as long as the voltage on
the DC link is greater than 50 VDC. Refer to Figure
20-8.
Hazardous voltages may be present in this equip-
ment even if the engine and capacitor charge
lights are off.
Use measurement and protective equipment
rated for 2000 VDC minimum to verify that no
voltage is present before touching any terminal.
1. Exterior Capacitor Charge Light (CCL2)
2. Interior Capacitor Charge Light (CCL1)
FIGURE 20-8. CAPACITOR CHARGE LIGHTS
Verify functionality of the measurement equip-
ment
using
site-approved
before and after performing control group mea-
surements.
Failure to observe these precautions may result
in death or serious personal injury.
3. Information Display Panel
4. DC Link Capacitors
Safety - Section 20
Page 20-17
procedures
both