Unit Reset; Cleaning And Maintenance; Troubleshooting - Gabarron RXE Plus Installation Instructions And User Manual

Thermal radiators
Table of Contents

Advertisement

Available languages

Available languages

EN
ADAPTIVE START CONTROL
RXE Plus electronic control analyses the heating requirements of the room where the radiator is installed using this
information to turn on the heating element in advance in order to reach the set point temperature at the desired time.
When Adaptive Start Control is working, the word AdAP will be displayed alternating with the status of the current
mode.
Note: To activate the adaptive start control please refer to ADVANCED FUNCTION ACTIVATION section.
ADVANCED FUNCTION ACTIVATION
Advanced functions Open Windows Detection and Adaptive Start Control are disabled by default. To enable / disable
these functions, the following steps must be followed:
Move the selector to
position maintaining the
The display will show
enable / disable Open Windows Detection function.
Confirm the new value for the function by pressing the PRG key. The next function (AdAP) is shown alternating with its
status (On or OFF). Use the navigation keys
new value for the function by pressing the PRG key.

5.- UNIT RESET

The heater reset establishes the factory configuration of the heater removing the programming, establishing the daily
programming and disabling the advanced functions. To reset the unit, hold the PRG key for 4 seconds, the display will
InIC
show
to indicate the heater has been reset.

6.- CLEANING AND MAINTENANCE

The radiators do not precise any special maintenance providing thermal comfort during large periods. Clean dust with
a dry, soft cloth only when the unit is disconnected and cold.
Do not use solvents or abrasive products for cleaning.
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right
way.

7.- TROUBLESHOOTING

The thermal radiator does not heat.
The room does not reach the required
temperature.
DAY and NIGHT luminous indicators
are lit at the same time
0
position, the display will be Off. Press the
key at least five seconds.
OPEn
alternating with the status of the function (On or OFF). Use the navigation keys
+
or
Check the heater or the air inlets are not covered.
If the display shows the time, press the
Check that the DAY or NIGHT temperatures are right.
Check the selected temperature is in accordance with the desired
temperature. Maybe the room needs more heating power.
Continuous mode has been selected.
If the knob is in the "I" Position, turn it to the "P" position to return to
the program mode if required.
If the knob is in the "P" Position, hold the Sun key for 4 seconds to
key and at the same time turn the selector to
to enable / disable Adaptive Start Control function. Confirm the
22
key to switch on the heater.
P
+
or
to