IBM x3250 M2 Problem Determination And Service Manual page 200

Hide thumbs Also See for x3250 M2:
Table of Contents

Advertisement

Table 10. DSA diagnostic messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 3, "Parts listing, Types 4190, 4191 and 4194 server," on page 31 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a trained
service technician.
Message
number
Component
215-901-xxx
Optical drive
215-902-xxx
Optical drive
182
IBM System x3250 M2 Types 4190, 4191 and 4194: Problem Determination and Service Guide
Test
State
Self-Test
Aborted
Self-Test
Failed
Description
Action
Drive media is not
1. Insert a new CD or DVD into the drive
detected.
and wait for 15 seconds for the media
to be recognized.
2. Run the test again.
3. Check the drive cabling for loose or
broken connections at both ends or
damage to the cable. Replace the cable
if it is damaged.
4. Run the test again.
5. For additional troubleshooting
information, see the "Troubleshooting
CD and DVD drive issues" site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the optical drive.
8. Run the test again.
9. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.
Read
1. Insert a new CD or DVD into the drive
miscompare.
and wait for 15 seconds for the media
to be recognized.
2. Run the test again.
3. Check the drive cabling for loose or
broken connections at both ends or
damage to the cable. Replace the cable
if it is damaged.
4. Run the test again.
5. For additional troubleshooting
information, see the "Troubleshooting
CD and DVD drive issues" site at
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
6. Run the test again.
7. Replace the optical drive.
8. Run the test again.
9. If the problem remains, collect the data
from the DSA event log and send it to
IBM Service. For information about
contacting and sending data to IBM
Service, see http://www.ibm.com/
support/docview.wss?uid=psg1SERV-
CALL.