IMPORTANT SOP
A
Service Station Manual
• Remove Auto choke coupler connection.
• Remove TPS coupler connection.
• Loosen both clamps of carburetor using 3 mm
allen key.
• Take out carburetor assembly.
• Remove cylinder head mounting bolt (A) using 12 mm spanner.
• Loosen silencer front mounting bolts using 12
mm spanner.
• Take out silencer front mounting nuts.
Skill tip:
Only Silencer mounting nuts to be removed,
Silencer mouth to be pulled slightly but not to
be removed. This skill tip is applicable during
cam shaft/Rocker arm removal on vehicle only
for easy removal of plate cylinder head bolts.
37