Error 7: Low coolant level
Category B
 Low flow rate.
Fill with coolant.
Check coolant flow - remove kinks in the hose package.
Adjust the flow threshold
Clean the cooler.
 Pump does not turn.
Turn the pump shaft.
 Air in the coolant circuit.
Vent the coolant circuit.
 The hose package is not filled with coolant.
Switch the machine off and on > pump running > filling process.
 Operation with a gas-cooled welding torch.
Deactivate the torch cooling.
Connect the coolant feed and return with a hose bridge.
Error 8: Shielding gas error
Category A, B
 No gas.
Check the gas supply.
 The pre-pressure is too low.
Remove kinks in the hose package (nominal value: 4-6 bar pre-pressure).
Error 9: Secondary overvoltage
 Overvoltage at the output: Inverter error.
Request service.
Error 10: Earth fault (PE error)
 Connection between welding wire and machine casing.
Remove the electrical connection.
 Connection between welding circuit and machine casing.
Check the connection and routing of the earth wire / welding torch.
Error 11: Fast shut-down
Category A, B
 Remove the logical signal "Robot ready" during the process.
Eliminate errors on the higher-level control.
099-005589-EW501
9.02.2023
[1]
.
Rectifying faults
Error messages (power source)
33

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Taurus 355-505 Basic S and is the answer not in the manual?

This manual is also suitable for:

Taurus 355-505 steel synergic sTaurus 355-505 steel puls s

Table of Contents