Page 1
Alarm control panel PERFECTA 64 M Firmware version 2.00 USER MANUAL perfecta_64_M_u_en 02/23 SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND tel. +48 58 320 94 00 www.satel.pl...
Page 2
Please visit us at: https://support.satel.pl Hereby, SATEL sp. z o.o. declares that the radio equipment type PERFECTA 64 M is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.satel.pl/ce...
CONTENTS 1. Introduction ........................4 2. Technical reliability of the alarm system ................4 3. Alarm system operating costs ................... 4 4. Glossary ..........................4 5. EN 50131 standard for Grade 2 consequences ..............6 6. Keypads ..........................6 6.1 Keypads description ....................7 6.1.1 LED indicators ......................
Page 4
PERFECTA 64 M SATEL 6.10.1 Adding a user ......................26 6.10.2 Editing a user ......................27 6.10.3 Removing a user ...................... 27 6.10.4 Adding keyfob ......................27 6.10.5 Configuring keyfob settings ..................27 6.10.6 Removing keyfob ..................... 28 6.10.7 Adding proximity card ....................28 Entering card number manually .....................
Page 5
SATEL PERFECTA 64 M 7. Listening in ........................39 8. Keyfobs ........................... 39 9. SMS control ........................40 10. PERFECTA CONTROL application ................. 41 10.1 First start of PERFECTA CONTROL (Android) ............41 10.1.1 Adding a new alarm system by using the QR code (Android) ........41 10.1.2 Adding a new alarm system without using the QR code (Android) ......
PERFECTA 64 M SATEL 1. Introduction Thank you for choosing this product by SATEL. Read this manual before you start using the alarm system. It is recommended that the installer prepare and deliver to the users a customized alarm system user manual. The manual must include all changes and modifications in relation to the factory default settings.
Page 7
SATEL PERFECTA 64 M Alarm zone – the zone whose violation can result in the alarm being triggered. The alarm zones can be either instant (violation will trigger the alarm at once) or delayed (violation will only trigger the alarm after a defined period of time has elapsed, e.g. the entry delay).
How requirements of the standard affect the use of the control panel is described in detail hereunder. 6. Keypads SATEL offers the following keypads for the PERFECTA 64 M alarm control panel: PRF-LCD – hardwired keypad with mechanical keys, INT-KSG2R – hardwired keypad with touch keys,...
SATEL PERFECTA 64 M INT-TSH2 – hardwired touchscreen keypad, PRF-LCD-A2 – wireless keypad with mechanical keys and built-in proximity card reader (ACU-220 / ACU-280 module must be connected), PRF-LCD-WRL – wireless keypad with mechanical keys (PERFECTA-RF module must be connected).
PERFECTA 64 M SATEL two LEDs (marked I and II) – ask the installer which LED indicates the state of which partition ON or flashing – alarm or alarm memory in at least 1 partition The way of presenting the information is shown graphically below.
SATEL PERFECTA 64 M Normal mode The following items are displayed in the upper line: date and time in format selected by the installer or the keypad name. Press and hold for 3 seconds to switch the display to the system preview mode.
PERFECTA 64 M SATEL • information on the power consumption of the appliance connected to the ASW-200 smart plug. Press and hold for 3 seconds to switch the display to the normal mode. Messages The keypad displays the following messages (the higher position on the list, the higher the priority): •...
SATEL PERFECTA 64 M Beeps generated when operating 1 short beep – pressing any number key. 3 short beeps – confirmation of: – starting the arming procedure (there is exit delay in the partition) or arming (there is no exit delay in the partition), –...
PERFECTA 64 M SATEL Codes The code is used for user authentication. The user needs to enter the code to access the functions that enable operating the alarm system. The installer may permit starting some of the functions without using the code.
SATEL PERFECTA 64 M Arming the selected partition 1. Select the partition which is to be armed (press one of the keys: - partition 1; partition 2; - partition 3; - partition 4). 2. Select the arming mode (press one of the keys: - full arming;...
PERFECTA 64 M SATEL • at least one alarm zone is violated beyond the exit route in the partition, • a zone is bypassed in the partition, • there is tamper in the partition, • there is trouble in the system.
SATEL PERFECTA 64 M 6.5.1 Disarming and clearing alarm with code Disarming and alarm clearing without partition selection Enter the code and then press . Disarming / alarm clearing will take place in the partitions to which you have access.
PERFECTA 64 M SATEL Functions of keys in the user menu enter digits, letters and other characters enable / disable an option check / uncheck an item start a function save changes and quit the function exit the user menu...
SATEL PERFECTA 64 M Remember that the sequence of digits which starts a function e.g. from the main menu level will not start the same function from the submenu level. 6.8.2 Data editing The editing method depends on the type of data. Having completed the editing, press to save the changes.
PERFECTA 64 M SATEL Entering names The characters that can be entered by using the keys are presented in Table 1. Keep pressing the key until the required character appears. Long press the key to display the digit assigned to it.
Page 21
SATEL PERFECTA 64 M ○ ● ○ ● Button select function to run with buttons LED 1 select operating mode of red LED [APT-200 keyfob] LED 2 select operating mode of yellow LED [APT-200 keyfob] LED 3 select operating mode of green LED [APT-200 keyfob]...
Page 22
PERFECTA 64 M SATEL [621] 1.Settings set start / stop time of timers [6211] 1.Monday set start / stop time for Monday [62111] 1.Timer 1 start / stop time of timer 1 on Monday [62112] 2.Timer 2 start / stop time of timer 2 on Monday [62113] 3.Timer 3...
Page 23
SATEL PERFECTA 64 M [62154] 4.Timer 4 start / stop time of timer 4 on Friday [62155] 5.Timer 5 start / stop time of timer 5 on Friday [62156] 6.Timer 6 start / stop time of timer 6 on Friday [62157] 7.Timer 7...
Page 24
PERFECTA 64 M SATEL [621918] 8.Timer 8 start / stop time of timer 8 for exception 1 [62192] 2.Except. 2 set start / stop time for exception 2 [621921] 1.Timer 1 start / stop time of timer 1 for exception 2 [621922] 2.Timer 2...
Page 25
SATEL PERFECTA 64 M [62223] 3.Timer 3 start date of exception 2 for timer 3 [62224] 4.Timer 4 start date of exception 2 for timer 4 [62225] 5.Timer 5 start date of exception 2 for timer 5 [62226] 6.Timer 6 start date of exception 2 for timer 6 [62227] 7.Timer 7...
Page 26
PERFECTA 64 M SATEL [62327] 7.Timer 7 end date of exception 2 for timer 7 [62328] 8.Timer 8 end date of exception 2 for timer 8 [6233] 3.Except. 3 set end date for exception 3 [62331] 1.Timer 1 end date of exception 3 for timer 1 [62332] 2.Timer 2...
PERFECTA 64 M SATEL 6.10.1 Adding a user 1. Enter the user menu and press in turn to run 1.C function. 2. Enter the new user's code. 3. Press to save the code. Functions that allow entering the user data will be displayed.
SATEL PERFECTA 64 M 12. Press to save the name. Functions that allow entering the user data will be displayed. 13. Press to finish adding the user. Prompt for saving the changes will be displayed. 14. Press to save changes.
PERFECTA 64 M SATEL 5. For the APT-200 keyfob, press any of the buttons to define the operating mode of the LEDs (the button does not need to start any function). 5.1. Use the key to find the LED 1 function.
PERFECTA 64 M SATEL 6.12.2 Zone isolating The isolated zone will remain bypassed until it is unbypassed by the user. Enter the user menu and press in turn to run 2.I function. The way of SOLATE indicating the zone state and the procedure are identical to those used for inhibiting the...
SATEL PERFECTA 64 M 3. Press to confirm the selection. The list of editable timers will be displayed. 4. Press to select from the list a timer. 5. Press to confirm the selection. The timer start and stop time will be displayed (if no times are configured, you will see empty fields).
PERFECTA 64 M SATEL 4. Press to start the graphic mode (see: “Graphic mode” p. 17). To exit the graphic mode and return to the basic mode, press 5. Press to confirm the changes. Rules for programming the timer settings Time setting rules You can only set the timer start time or the stop time.
SATEL PERFECTA 64 M Programming temperature T2 (comfort temperature) The temperature T2 (comfort temperature) is the second temperature threshold. If the second temperature threshold is active, the thermostat will be turned on when the temperature drops below temperature 2 (comfort temperature). Ask the installer to find out when the second temperature threshold is active.
PERFECTA 64 M SATEL Hysteresis programming rules You can enter a value from 0°C to 7,5°C (with accuracy to 0,5°). If you program 0°C, the thermostat will be turned on when the temperature drops below the threshold by 0,5°C. 6.15 Checking the troubles / system state When the LED is flashing, check what is the cause of this signaling.
SATEL PERFECTA 64 M 2. Symbols illustrating the status of outputs you can control will be presented in the upper line of the display: – output is deactivated, – output is activated. The name of the output indicated by the cursor is presented in the lower line of the display.
. The existing ID number will be deleted and the SATEL server will assign a new ID number. The ID number will not be changed until the control panel is connected to the SATEL server. If you change the ID number, the PERFECTA CONTROL application users will have to configure the alarm system settings again (the applications using the old ID number will not be able to connect to the control panel).
SATEL PERFECTA 64 M 6.17.7 Checking the firmware version of devices in system Using the 8.FW function, you can check the firmware version of devices included in VERSIONS the alarm system: • control panel, • modules connected to the control panel, •...
PERFECTA 64 M SATEL 2. Keep pressing the key until the cursor indicates the R function. EPLACE BATTERY 3. Press 4. After the “SELECT...” message appears, use the key to find on the list the wireless keypad in which you want to replace the battery.
SATEL PERFECTA 64 M 6.22 Service mode The S function is only available after entering the service code. It allows you to ERVICE MODE enter the service mode. After entering the service mode, the functions that allow you to configure the alarm system will be displayed. For more information, please refer to the control panel programming manual.
PERFECTA 64 M SATEL Fig. 3. T-4 keyfob and button numbers. 9. SMS control You can control your alarm system by using SMS messages containing appropriate control commands. The SMS message must be sent to the control panel phone number (number of the currently used SIM card).
SATEL PERFECTA 64 M The alarm system may be configured so that, in some circumstances, arming the system by using the SMS message will fail (see “System problems and arming failure”). Consult the installer to learn how you are to be effectively notified of the system arming failure.
2. Enter the control panel’s IMEI number. 3. Enter the control panel’s ID number (the individual identification number for the purpose of communication via the SATEL server). 4. Enter your user code. 5. Select the icon that will be displayed next to the name on the list of alarm systems.
SATEL PERFECTA 64 M 10.2 First start of PERFECTA CONTROL (iOS) 1. Decide if you want the application to send notifications. You will proceed to the next step. 2. Decide if you want the access to the application to be password-protected. You will proceed to the next step.
2. Enter the control panel’s IMEI number. 3. Enter the control panel’s ID number (the individual identification number for the purpose of communication via the SATEL server). 4. Enter your user code. 5. Select the icon that will be displayed next to the name on the list of alarm systems.
Need help?
Do you have a question about the PERFECTA 64 M and is the answer not in the manual?
Questions and answers