TECHNICAL DATA
5
Error current FDE
Address range
FOUNDATION Fieldbus
FOUNDATION Fieldbus
FOUNDATION Fieldbus
FOUNDATION Fieldbus
Type
Function blocks
Protocol / Communication
standard
ITK version
Physical layer types
Other features
Device power supply (24 V input)
Current consumption on
FOUNDATION Fieldbus network
Output data
Input data
Error current FDE
Link Master function
Approvals and certification
CE
Explosion protection
Explosion protection
Explosion protection
Explosion protection
ATEX (approval for Hygienic
antennas and fieldbus outputs
pending)
IECEx (approval for Drop,
Hygienic antenna and fieldbus
outputs options pending)
FM - Dual Seal-approved
(approval for hygienic antenna
and fieldbus output options
pending)
34
Typically 0 mA (FDE =Fault Disconnection Electronic)
0...125. Default address: 126.
4-wire (+ local HART) level transmitter; K-band FMCW radar
1 × Resource Block (RB), 4 × Analog Input Blocks (RB), 1 × Transducer Block (TB)
Foundation Fieldbus protocol that agrees with IEC 61158-2, galvanically isolated
5.1
Standard power signaling, bus powered, non I.S.
Bus interface with integrated reverse polarity protection
18...30 VDC
20 mA
Level, distance, level conversion, level mass, reflection, ullage conversion or
distance mass
None
Typically 0 mA (FDE =Fault Disconnection Electronic)
Not supported
This device fulfils the statutory requirements of the EC directives. The
manufacturer certifies successful testing of the product by applying the CE mark.
ATEX II 1 G, 1/2 G, 2 G Ex ia IIC T6...T3;
ATEX II 1 D, 1/2 D, 2 D Ex iaD 20 or Ex iaD 20/21 IP6X T65°C...T90°C;
ATEX II 1/2 G, 2 G Ex d[ia] IIC T6...T3;
ATEX II 1/2 D, 2 D Ex tD[iaD] A21/20 IP6X T65°C...T90°C;
ATEX II 3 G Ex nA IIC T6...T3
Ex ia IIC T6...T3 Ga; Ex iaD 20 IP6X T65°C...T 90°C;
Ex d[ia] IIC T6...T3 Ga/Gb; Ex tD[iaD] A21/20 IP6X T65°C...T 90°C (pending)
NEC 500
NEC 500
NEC 500
NEC 500
XP-IS: Cl. I, Div. 1, Gr. ABCD T6;
DIP: Cl. II/III, Div. 1, Gr. EFG T6;
IS: Cl. I/II/III, Div. 1, Gr. ABCDEFG T6;
NI: Cl. I, Div. 2, Gr. ABCD T6
NEC 505
NEC 505
NEC 505
NEC 505
XP-IS: Cl. I Zone 0 AEx d[ia] IIC T6...T3;
IS: Cl. I Zone 0 AEx ia IIC T6...T3;
NI: Cl. I Zone 2 AEx nA[ia] IIC T6...T3
Hazardous (Classified) Locations, indoor/outdoor Type 4X and 6P, IP66, Dual Seal