KROHNE OPTIWAVE 7300 C Quick Start Manual page 33

Non-contact radar (fmcw) level meter for liquids
Hide thumbs Also See for OPTIWAVE 7300 C:
Table of Contents

Advertisement

OPTIWAVE 7300 C
Process connections
Thread
Flange version
Flange version
Flange version
Flange version
EN
ASME
JIS
Hygienic
Other
Electrical connections
Power supply
Cable entry
Cable gland
Cable entry capacity (terminal)
Input and output
Current output
Current output
Current output
Current output
Output signal
(Output 1)
Output signal
(Output 2 - optional)
Resolution
Temperature drift
Error signal
PROFIBUS PA
PROFIBUS PA
PROFIBUS PA
PROFIBUS PA
Type
Function blocks
Protocol / Communication
standard
Physical layer types
Other features
Device power supply (24 V input)
Current consumption on
PROFIBUS network
Output data
Input data
04/2010 - 4000050003 - QS OPTIWAVE 7300 R06 en
G 1½; 1½ NPT
DN40...150 in PN16, PN40, PN63 or PN100; others on request
1½¨...8¨ in 150 lb, 1½¨...6¨ in 300 lb, 1½¨...4¨ in 600 lb or 900 lb; others on request
40...100A in 10K; others on request
®
BioControl
DN50; Tri-Clamp
Others on request
Terminals output 1 - Non-Ex / Ex i:
Terminals output 1 - Non-Ex / Ex i:
Terminals output 1 - Non-Ex / Ex i:
Terminals output 1 - Non-Ex / Ex i:
14...30 VDC; min./max. value for an output of 22 mA at the terminal
Terminals output 1 - Ex d:
Terminals output 1 - Ex d:
Terminals output 1 - Ex d:
Terminals output 1 - Ex d:
20...36 VDC; min./max. value for an output of 22 mA at the terminal
Terminals output 2 - Non-Ex / Ex i / Ex d:
Terminals output 2 - Non-Ex / Ex i / Ex d:
Terminals output 2 - Non-Ex / Ex i / Ex d:
Terminals output 2 - Non-Ex / Ex i / Ex d:
10...30 VDC; min./max. value for an output of 22 mA at the terminal (additional
power supply needed - output only)
M20×1.5; ½ NPT
G ½ (not for FM- and CSA-approved devices. Not for stainless steel housings.)
M25×1.5 (for stainless steel housings only)
Standard: none
Options: M20×1.5 (for non-Ex and Ex -approved devices with M20×1.5 and M25×1.5
cable entries); others are available on request
0.5...1.5 mm²
®
4...20 mA HART
or 3.8...20.5 mA acc. to NAMUR NE 43
®
4...20 mA (no HART
signal) or 3.8...20.5 mA acc. to NAMUR NE 43
±3 µA
Typically 50 ppm/K
High: 22 mA; Low: 3.6 mA acc. to NAMUR NE 43
4-wire (+ local HART) level transmitter; K-band FMCW radar
7 (level, distance, level conversion, level mass, reflection, ullage conversion and
distance mass)
PROFIBUS PA protocol that agrees with IEC 61158-2, galvanically isolated
Standard power signaling, bus powered, non I.S.
Bus interface with integrated reverse polarity protection
18...30 VDC
20 mA
Level, distance, level conversion, level mass, reflection, ullage conversion or
distance mass
None
www.krohne.com
TECHNICAL DATA
®
2¨; DIN 11851 DN50; SMS 51; others on request
5
7
33