Omron CK3W-AX2323 Series Startup Manual page 40

Directpwm interface
Hide thumbs Also See for CK3W-AX2323 Series:
Table of Contents

Advertisement

3 DirectPWM Interface Connection Procedure
3
If the screen on the right appears, click
the Implement button.
4
Check that the Recommended Gains
values are applied to Current Gains,
and then click the OK button.
5
Select Position Loop
InteractiveTuning ‒ Parabolic Vel.
and set the following parameters.
Move Size: 2500 mu
Move Time: 500 ms
Left Axis: Velocity
Right Axis: Following Error
6
Click the Parabolic Velocity Move but-
ton.
7
Check the parabolic response charac-
teristic of velocity.
3-26
CK3M/CK5M Series Startup Guide DirectPWM Interface (O047)