PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS
19
Travel limits regulate the points at which the door will stop when
moving UP or DOWN. The travel limit buttons are located under the
access cover on the rear panel (figure 1).
figure 1
NOTE: This opener uses a POSITION TAB attached to the belt
which activates a mechanical passpoint during the door travel. The
indicator LED will blink when this occurs. If the passpoint is not
activated during the door travel process, the travel limits cannot be
programmed.
TO PROGRAM THE TRAVEL LIMITS:
1.
Ensure the door is engaged to the opener trolley before setting the
limits, otherwise the yellow trolley may move independently and jam
into the powerhead assembly.Press the PROG Button until the UP
Arrow Button and indicator LED begin to flash (figure 2).
Press and hold the UP Arrow Button until the door is in the desired
2.
UP position (figure 3).
NOTE: The UP and DOWN Arrow Buttons can be used to move the
door up and down as needed.
3.
Once the door is in the desired UP position press and release the
PROG Button. The DOWN Arrow Button will begin to flash
(figure 4).
4.
Press and hold the DOWN Arrow Button until the door is in the
desired DOWN position (figure 5).
NOTE: The UP and DOWN Arrow Buttons can be used to move the
door up and down as needed.
5.
Once the door is in the desired DOWN position press and release
the PROG Button. The UP Arrow Button will begin to flash (figure
2).
SETTING THE FORCE (AUTO):
6.
Press and release the UP Arrow Button to test the UP limit. When
the door has travelled to the programmed UP limit, the DOWN
Arrow Button will begin to flash.
7.
Press and release the DOWN Arrow Button to test the DOWN limit.
The door will travel to the programmed DOWN limit.
The indicator LED will stop flashing. The travel limits and force
setting has now been set. Proceed to test safety reverse system.
SETTING THE FORCE (MANUAL LEARN IF REQUIRED):
1.
Open the rear access panel. Locate the yellow Learn button.
2.
Push the yellow Learn button twice to enter unit into force
adjustment mode. The LED (indicator light) will flash quickly.
3.
Push the programmed transmitter or push the UP/DOWN arrow at
the programming display bar. The door will travel to the DOWN
(close) position. Push the transmitter again, the door will travel to
the UP (open) position.
Press and release the DOWN Arrow Button to test the DOWN limit.
4.
The door will travel to the programmed DOWN limit.
The LED (indicator light) will stop flashing when the force has been set.
The door must travel through a complete cycle, UP and DOWN, in order
for the force to be set properly. If the unit cannot open and close your
door fully, inspect your door to insure that it is not sticking or binding.
ADJUSTMENT SECTION
12
Without a properly installed safety
reversal system, persons (particularly
small children) could be SERIOUSLY
INJURED or KILLED by a closing
door.remains ON.
Incorrect adjustment of garage door travel
limits will interfere with proper operation of
safety reversal system.
NEVER use force adjustments to compensate
for a binding or sticking garage door.
After ANY adjustments are made, the safety
reversal system MUST be tested. Door MUST
reverse on contact with 40 mm high object
laid flat on floor.
CAUTION
To prevent damage to vehicles, be sure fully open door
provides adequate clearance.
figure 2
Indicator LED
figure 3
Indicator LED
figure 4
Indicator LED
figure 5
Indicator LED