ELITE SERIES COMMERCIAL HIGH-TRAFFIC
AC SLIDE GATE OPERATOR
SL3000101UL
1 HP Single Phase
SL3000501UL
1/2 HP Single Phase
LiftMaster
300 Windsor Drive
Oak Brook, IL 60523
INSTALLATION MANUAL
• THIS PRODUCT IS TO BE INSTALLED
• T
AND SERVICED BY A TRAINED GATE
A
S
SYSTEMS TECHNICIAN ONLY.
• T
• This model is for use on vehicular
passage gates ONLY and not intended
p
for use on pedestrian passage gates.
f
• T
• This model is intended for use in Class
I
I, II, III and IV vehicular slide gate
a
applications.
• Visit LiftMaster.com to locate a
• V
p
professional installing dealer in your
a
area.
• T
• This gate operator is compatible with
MyQ
M
and Security+ 2.0
®
Access installation and technical support
guides or register this product
SL3000ULTECH
accessories.
®
Take a photo of the
1.
camera icon including
the points ( ).
Send it in by texting the
2.
photo to 71403.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL3000101UL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chamberlain SL3000101UL

  • Page 1 Security+ 2.0 accessories. ® ® Access installation and technical support guides or register this product SL3000101UL Take a photo of the 1 HP Single Phase camera icon including the points ( ). SL3000501UL Send it in by texting the 1/2 HP Single Phase photo to 71403.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SAFETY Photoelectric Sensors and Edge Sensors ..........26 Locks ....................26 Safety Symbol and Signal Word Review ..........2 Usage Class ...................3 EXPANSION BOARD OVERVIEW UL325 Entrapment Protection Requirements ........3 Exit Fail Switch ..................27 Safety Installation Information ...............4 AC Fail Switch ..................27 Gate Construction Information ...............5 Anti Tail Switch ..................27 Quick Close Switch ................27...
  • Page 3: Usage Class

    SAFETY Usage Class Class I - Residential Vehicular Gate Operator A vehicular gate operator (or system) intended for use in garages or parking areas associated with a residence of one-to four single families. Class II - Commercial/General Access Vehicular Gate A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotel, garages, retail store, or other buildings...
  • Page 4: Safety Installation Information

    SAFETY Safety Installation Information 1. Vehicular gate systems provide convenience and security. Gate systems 9. The Stop and/or Reset (if provided separately) must be located in the are comprised of many component parts. The gate operator is only one line-of-sight of the gate. Activation of the reset control shall not cause component.
  • Page 5: Gate Construction Information

    SAFETY Gate Construction Information Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org. General Requirements Vehicular Horizontal Slide Gates Gates shall be constructed in accordance with the provisions The following provisions shall apply to Class I, Class II and Class III given for the appropriate gate type listed, refer to ASTM F2200 vehicular horizontal slide gates:...
  • Page 6: Introduction

    INTRODUCTION Carton Inventory NOT SHOWN: Documentation Packet, Chain #41 - 25 feet, Eye Bolt Kit Tools Needed 1/2" wrench for cover screw 5/16", 3/4" wrench for 1/2" concrete anchors, Screwdrivers (phillips head and flat head), Cable cutters and strippers...
  • Page 7: Operator Specifications

    Model SL3000501UL 1/2 HP: 120 Vac, 6 Amps (12 Amps including accessory outlets) Model SL3000101UL 1 HP: 120 Vac, 12 Amps (18 Amps including accessory outlets) When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated 208/240/480/575 VAC, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH...
  • Page 8: Site Preparation

    INTRODUCTION Site Preparation Check the national and local building codes BEFORE installation. Conduit and Concrete Pad Safety Trench and install conduit. Before trenching, contact underground utility Entrapment protection devices are required to protect against any locating companies. Conduit must be UL approved for low and high entrapment or safety conditions encountered in your gate voltage.
  • Page 9: Installation

    INSTALLATION To AVOID damaging gas, power or other underground utility lines, DO NOT touch the heater when switch is on, heater may be hot. contact underground utility locating companies BEFORE digging more than 18 inches (46 cm) deep. Types of Installations Standard Installation Rear Installation...
  • Page 10: Step 1 Determine Location For Operator

    INSTALLATION Step 1 Determine Location for Operator Check the national and local building codes before installation. Standard Installation 1. The gate operator should be installed near the front roller of the gate. Lay out the concrete pad. 2. Install the electrical conduit. 3.
  • Page 11: Step 2 Install The Operator

    INSTALLATION Step 2 Install the Operator Attach the operator to the concrete pad with appropriate fasteners. The gate operator should be installed near the front roller of the gate or near the back of the gate (in the OPEN position). The space between the gate and the output sprocket must be a minimum of 4 inches (10.2 cm).
  • Page 12: Step 3 Attach The Chain

    INSTALLATION Step 3 Attach the Chain Standard Installation DO NOT run the operator until instructed. 1. Manually open the gate and line up the front bracket so the chain will be level with the idler pulley and parallel to the ground. Weld the front bracket in this position.
  • Page 13: Step 4 Install Entrapment Protection

    INSTALLATION To prevent SERIOUS INJURY or DEATH from a moving gate: ALL gate operator systems REQUIRE two independent entrapment Locate entrapment protection devices to protect in BOTH the open and protection systems for each entrapment zone. close gate cycles. Entrapment protection devices MUST be installed to protect anyone Locate entrapment protection devices to protect between moving gate who may come near a moving gate.
  • Page 14 INSTALLATION Wire Entrapment Protection Devices There are three options for wiring the entrapment protection devices depending on the specific device and how the device will function. Refer to the specific entrapment protection device manual for more information. These entrapment protection device inputs are for monitored devices, which include pulsed photoelectric sensors, resistive edge sensors, and pulsed edge sensors.
  • Page 15: Step 5 Earth Ground Rod

    INSTALLATION Step 5 Earth Ground Rod Use the proper earth ground rod for your local area. The ground wire must be a single, whole piece of wire. Never splice two wires for the ground wire. If you should cut the ground wire too short, break it, or destroy its integrity, replace it with a single wire length.
  • Page 16 INSTALLATION All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. Power wiring 1.
  • Page 17: Step 7 Dual Gate Setup

    INSTALLATION Step 7 Dual gate setup There are two options for dual gate communication: wired or wireless. Follow the directions according to your application. Do not use wired and wireless communication simultaneously. Wireless setup To activate the wireless feature: 1. Choose an operator to be the network primary operator. All wireless accessories will need to be programmed to the primary operator. NOTE: We recommend that all accessories and board configurations are set on the primary operator.
  • Page 18: Step 8 Install The Cover

    INSTALLATION DUAL GATE WIRE TYPE (SHIELDED TWISTED PAIR CABLE) Wired setup 22AWG up to 200 feet (61 m) 18AWG - 200-1000 feet (61-305 m) Before digging, contact local underground utility locating companies. Use Wire must be rated at 30 Volt minimum PVC conduit to prevent damage to cables. 1.
  • Page 19: Adjustment

    ADJUSTMENT Adjust the Handing and Limits To reduce the risk of SEVERE INJURY or DEATH: Without a properly installed safety reversal system, persons NEVER use force adjustments to compensate for a binding or sticking (particularly small children) could be SERIOUSLY INJURED or gate.
  • Page 20: Fine Tune The Force

    ADJUSTMENT Readjust the Limits To readjust the limits, follow the “Set the Limits” and “Set the Force and Run Distance” instructions above. It is important that the force and run distance are set after every limit readjustment. Fine Tune the Force Once the initial limits have been set, the REVERSAL FORCE DIAL on the control board is used for fine tuning the force where wind or environmental changes may affect the gate travel.
  • Page 21: Operator Overview

    OPERATOR OVERVIEW...
  • Page 22: Control Board Overview

    CONTROL BOARD OVERVIEW...
  • Page 23: Learn Button

    CONTROL BOARD OVERVIEW Learn Button The LEARN button is used for programming (refer to Programming). Diagnostic Display The diagnostic display will show the operator type, firmware version, and codes. The operator type will display as “SL” followed by a “30” which indicates the operator type as SL3000UL. The firmware version will show after the operator type, example “1.2”. For more information about the codes refer to the Troubleshooting section.
  • Page 24: Reversal Force Dial

    CONTROL BOARD OVERVIEW Reversal Force Dial The REVERSAL FORCE dial adjusts the force. See the Adjustment section. Settings 1-3: Fixed force settings (the force will not adjust due to gate wear or temperature changes) Settings 4-10: Automatically increase the force due to gate wear or temperature changes Test Buttons Used to operate the gate (OPEN, STOP and CLOSE).
  • Page 25: Wire Accessories To Control Board

    WIRE ACCESSORIES TO CONTROL BOARD All control wiring used to connect external devices to Class 2 circuits of the operator must be (QPTZ) Power-Limited Circuit Cables, Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. Three Button Control Station TERMINALS FUNCTION...
  • Page 26: Photoelectric Sensors And Edge Sensors

    WIRE ACCESSORIES TO CONTROL BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed direction. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
  • Page 27: Expansion Board Overview

    EXPANSION BOARD OVERVIEW To AVOID damaging the circuit board, relays or accessories, DO NOT connect more than 42 Vdc (32 Vac) to the AUX relay contact terminal blocks. EXIT FAIL Switch OPEN: If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, then the gate will open and remain open until fault is cleared. CLOSE: If the EXIT plug-in loop detector (model LOOPDETLM) detects a fault, faults are ignored (EXIT loop is faulted and inoperative).
  • Page 28: Auxiliary Relay 1 And 2

    EXPANSION BOARD OVERVIEW Auxiliary Relay 1 and 2 Normally Open (N.O.) and Normally Closed (N.C.) relay contacts to control external devices, for connection of Class 2, low voltage (42 Vdc [34 Vac] max 5 Amps) power sources only. Function of relay contact activation determined by switch settings. SWITCH SETTINGS AUX RELAY AUX RELAY 1...
  • Page 29: Wire Accessories To Expansion Board

    WIRE ACCESSORIES TO EXPANSION BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed direction. Monitored entrapment protection devices should have been installed with the operator at the time of installation.
  • Page 30: Loops

    WIRE ACCESSORIES TO EXPANSION BOARD Loops TERMINALS FUNCTION WIRING EXAMPLE EXIT Loop wire connection for plug-in loop detector when loop is inside secured area near gate. Open command - opens a closed gate Soft open (maintained switch does not override external safeties and does not reset alarm condition) If maintained, pauses Timer-to-Close at OPEN limit Opens a closing gate and holds open an open gate...
  • Page 31: Field Wiring

    ADDITIONAL WIRING To protect against fire and electrocution: For continued protection against fire: DISCONNECT power (AC or solar and battery) BEFORE installing or Replace ONLY with fuse of same type and rating. servicing operator. Field Wiring...
  • Page 32: Programming

    PROGRAMMING Remote Controls (Not Provided) ® A total of 50 Security+ 2.0 remote controls or KPW250 keypads and 2 keyless entries (1 PIN for each keyless entry) can be programmed to the operator. When programming a third keyless entry to the operator, the first keyless entry will be erased to allow the third keyless entry to be programmed.
  • Page 33: Liftmaster Internet Gateway (Not Provided)

    PROGRAMMING LiftMaster Internet Gateway (not Constant Pressure Override (CPO) provided) Constant Pressure Override is for use with KPW5 and KPW250 keypads (not provided). The KPW5/KPW250 wireless commercial keypads are To program the operator to the LiftMaster Internet Gateway: security keypads and can only be programmed to ONE gate operator (see Using the learn button on the opertaor's control the KPW5/KPW250 manual for complete programming instructions).
  • Page 34: Settings

    SETTINGS Gate operator setup examples The following are example setups for the gate operator. Your specific site requirements may be different. Always setup the operator system to the site requirements, including all necessary entrapment protection devices. RESIDENTIAL: One to four residential homes sharing a gated entrance/exit, allowing vehicle access trumps security concerns COMMERCIAL/GENERAL ACCESS: A residential community (more than four homes) having one or more gated entrances/exits, allowing vehicle access trumps security concerns COMMERCIAL: Business site where security (gate closed) is important...
  • Page 35: Dual Gate Settings

    SETTINGS Dual Gate Settings NOTE: We recommend that all accessories and board configurations are set on the primary operator. Main Control Board FEATURE PRIMARY OPERATOR SECONDARY OPERATOR Timer-to-Close Set the TTC dial to desired setting Bi-Part Delay Switch Bi-Part Delay: ON (will open last and close first) Bi-Part Delay: OFF (will open first and close last) Tandem Mode: OFF Tandem Mode: OFF...
  • Page 36: Maintenance

    MAINTENANCE IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH: READ AND FOLLOW ALL INSTRUCTIONS. Test the gate operator monthly. The gate MUST reverse on contact with an object or reverse when an object activates the noncontact ANY maintenance to the operator or in the area near the operator sensors.
  • Page 37: Troubleshooting

    TROUBLESHOOTING To protect against fire and electrocution: For continued protection against fire: DISCONNECT power (AC or solar and battery) BEFORE installing or Replace ONLY with fuse of same type and rating. servicing operator. Diagnostic Codes To View the Codes The codes will show on the diagnostic display. The operator will show the code sequence number followed by the code number: To Exit...
  • Page 38: Diagnostic Codes Table

    TROUBLESHOOTING Diagnostic Codes Table Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear. External Entrapment Inherent Entrapment LiftMaster System Installed System Informational Protection...
  • Page 39 TROUBLESHOOTING Code Meaning Solution Saved CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EDGE triggered, causing reversal, NO IF an obstruction occurred, no action required. If an obstruction did NOT preventing close, or canceling TTC occur, check alignment, inputs, and wiring on main control board OPEN EYE/EDGE triggered, causing reversal or preventing opening CLOSE EYE/INTERRUPT triggered, causing...
  • Page 40: Operator Alarm

    TROUBLESHOOTING Operator Alarm If a contact sensor detects an obstruction twice consecutively the alarm will sound (up to 5 minutes) and the operator will need to be reset. When the inherent force of the operator (RPM/current sensor) detects the following (twice consecutively) the alarm will sound (up to 5 minutes) and the operator will need to be reset.
  • Page 41: Troubleshooting Chart

    TROUBLESHOOTING Troubleshooting Chart SYMPTOM POSSIBLE CAUSES SOLUTIONS Operator does not a. No power to control board a. Check AC power run and diagnostic b. Open fuse b. Check fuses display not on. c. Defective control board c. Replace defective control board Control board a.
  • Page 42 TROUBLESHOOTING SYMPTOM POSSIBLE CAUSES SOLUTIONS Shadow loop does a. Vehicle detector setup incorrectly a. Review Shadow loop detector settings. Adjust settings as needed. not keep gate at b. Defective vehicle loop detector b. Replace defective Shadow loop detector. open limit. Obstruction in a.
  • Page 43: Accessories

    ACCESSORIES Universal single and 3-button remote LiftMaster elite series maglock package controls Model MG1300RLYPKG Ideal for applications requiring a large number of remote controls. Models 811LM and 813LM ® Security+ 2.0 learning remote controls Heater kit accessory One button can control a gate operator and the other(s) can control garage door(s).
  • Page 44 ACCESSORIES Entrapment protection If the gate opening distance is greater than the maximum separation distance of the photoelectric sensors, then edge sensors MUST BE USED. Refer to the photoelectric sensor instructions for maximum separation distance. LiftMaster monitored through beam photoelectric sensor Model LMTBUL LiftMaster monitored retro-reflective photoelectric sensor...
  • Page 45: Repair Parts

    REPAIR PARTS REPAIR PARTS (NOT SHOWN) #41 Chain (10 feet) 19-41240D #40 Chain (10 feet) 19-40240D #41 Chain (Nickel Plated) 19-41240D-NP #41 Master Link 19-50307 #40 Master Link 19-50310 Plastic Standoffs for main control board (10 per K77-37683 bag) Wire Harnesses (main board to power board, main board to ground, main board to transformer, and K77-37693 power board to transformer)
  • Page 46: Warranty

    WARRANTY LiftMaster 7 Year residential / 5 Year Commercial Limited Warranty LiftMaster (“Seller”) warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of 7 Year residential / 5 Year Commercial from the date of purchase [and that the SL3000UL is free from defect in materials and/or workmanship for a period of 7 Year residential / 5 Year Commercial from the date of purchase].