  • Page 2 1. Description......................... 2. Design..........................3. Placement and Assembly....................4. Dimensions......................... 5. Material, surface protection....................6. Product data........................7. Logistic terms........................8. Warranty..........................9. Installation..........................
  • Page 3 The dampers consist of blade frames and control mechanisms. It serves to regulate the air flow by throttling the cross section. The dampers are intended for atmospheres protected against weather influences with climatic condition classification of class 3K5 with temperature limitation from -20°C to +50°C, without condensation, frost, ice, without water, including from other sources than from rain acc.
  • Page 4 The dampers are intended for installation in air-conditioning piping. The operation position is arbitrary. The minimum space for the control device is 200 mm (in blade rotation axis). When assembling round dampers into the piping, respect the overlap of open blade "a" (tab. 4.3.1.).
  • Page 5 Position: Damper body Divider Damper blade The damper for actuator attachment is fitted with a square pin with 8 x 8 mm Control mechanism cross section, onto which the actuator is to be fixed either directly or with Control lever (manual) the help of a reducer.
  • Page 6 Position: Damper body Damper blade The damper for actuator attachment is fitted with a square Control lever (manual) pin with 10x10 mm diameter and 50 mm length. Control lever (mechanical)
  • Page 7 (A x B): RKM (RKTM): from 200 x 200 mm to 2000 x 2000 mm The damper length is 150 mm. must be discussed with the manufacturer in advance: RKM: from 100 x 100 mm to 2400 x 2400 mm RKTM: from 100 x 100 mm to 2400 x 2000 mm : from 80 mm to 800 mm diameter.
  • Page 8 - flanges with 30 mm width are fitted with oval holes in corners • Round piping with flanges - flanges acc. to EN 12 0505 • Spiro piping with lip seal...
  • Page 9 The frames, blades and control mechanism of the dampers are made of galvanized or stainless metal sheet, respectively; the blade pins of square dampers are made of plastic, the blade pins of round dampers are made of galvanized steel or stainless steel, respectively. The dampers are delivered without further surface treatment.
  • Page 10 MANDÍK, a.s. Dobříšská 550 26724 Hostomice Czech Republic Tel.: +420 311 706 706 E-Mail: mandik@mandik.cz www.mandik.com The producer reserves the right for innovations of the product. For actual product information see www.mandik.com...