Troubleshoot by LED behaviour or LCD display
If fault occurs, users can check the fault information on the LCD or by the number of blinks
of the LED indicator light. Each fault is indicated with a sequence of different numbers of
LCD blinking. A pause of 3 seconds between each sequence indicates the beginning or end
of a sequence. If multiple faults happen at the same time, each sequence of blinking shows
in chronological order at an interval of 3 seconds.
Please see the table below for detailed information:
Fault Code on LCD
No.
(If Available)
1
100
2
105
3
106
4
108
5
109
6
110
7
8
112
9
113
10
114
11
115
12
116
13
117
14
118
15
1000
35
Number of blinks on
the LCD
111
3
Red emergency stop button is pressed or broken
1
2
4
5
6
7
9
10
11
12
14
Fault Description
Over Voltage on phase L1
Under Voltage on phase L1
Over Current
Over Temperature
DC leakage current detected
RS485 Communication Fault
Reserved
Type A Switch Fault
Relay
PE Fault
PEN Fault
Reserved
Anti-Tamper Switch Activated
Other Fault