Troubleshooting - Project EV EVA-07D-SE-RFID User Manual

Dual outlet floor ac charger
Table of Contents

Advertisement

Troubleshooting

Dual Floor Pro Earth
Troubleshoot by LED behaviour or LCD display
If fault occurs, users can check the fault information on the LCD or by the number of blinks
of the LED indicator light. Each fault is indicated with a sequence of different numbers of
LCD blinking. A pause of 3 seconds between each sequence indicates the beginning or end
of a sequence. If multiple faults happen at the same time, each sequence of blinking shows
in chronological order at an interval of 3 seconds.
Please see the table below for detailed information:
Fault Code on LCD
No.
(If Available)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
33
Number of blinks on
the LCD
100
105
106
108
109
110
111
112
113
114
115
116
117
118
1000
3
Red emergency stop button is pressed or broken
1
2
4
5
6
7
9
10
11
12
14
Fault Description
Over Voltage on phase L1
Under Voltage on phase L1
Over Current
Over Temperature
DC leakage current detected
RS485 Communication Fault
Reserved
Type A Switch Fault
Relay
PE Fault
PEN Fault
Reserved
Anti-Tamper Switch Activated
Other Fault

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eva-22d-se-rfidEva-07d-se-rfid-cEva-22d-se-rfid-c

Table of Contents