  • Page 1 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Document number: MNLCNXPTZ2_2240 Publication date: 11/22...
  • Page 2: Table Of Contents

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Table of Contents Legal Notices Typographical conventions Important safety rules Regulatory Notices Overview Product description and type designation Product marking Checking the markings Model identification Preparing the Installation Unpacking Safely disposing of packaging material Safety precautions before use Preparing the product for use Product Package Contents...
  • Page 3 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Resetting to Factory Default Settings Maintenance Routine maintenance Inspecting the cables Extraordinary maintenance Fuses replacement Cleaning Cleaning of the window and external surfaces of the product Troubleshooting Technical drawings MNLCNXPTZ2_2240 | 11/22...
  • Page 4: Legal Notices

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Legal Notices ©  2023, Pelco Corporation. All rights reserved. PELCO, the PELCO logo, PELCO are trademarks of Pelco Corporation. ONVIF is a trademark of Onvif, Inc. Other names or logos mentioned herein may be the trademarks of their respective owners.
  • Page 5: Typographical Conventions

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Typographical conventions This manual provides installation and operation information and precautions for the use of this device. Incorrect installation could cause an unexpected fault. Before installing this equipment read this manual carefully. Please provide this manual to the owner of the equipment for future reference. Warning: This symbol indicates the presence of dangerous voltage within and outside the product enclosure that may result in a risk of electric shock, serious injury or death to persons if proper precautions are not followed.
  • Page 6 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Do not expose the camera directly to high levels of x-ray, laser, or UV radiation. Direct exposure may cause permanent damage to the image sensor. Before starting any operation, make sure the power supply is disconnected. Do not subject the device cables to excessive stress, heavy loads or pinching.
  • Page 7: Regulatory Notices

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual The appliance includes moving parts. Make sure that the unit is positioned where it is inaccessible under normal operating conditions. Attach the warning label supplied with the appliance, placing it near the unit so that it can be seen easily. Attach the Dangerous Moving Parts label near the device (Hazardous moving parts label.).
  • Page 8 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual European Union: This symbol means that according to local laws and regulations your product should be disposed of separately from household waste. When this product reaches its end of life, take it to a collection point designated by local authorities.
  • Page 9: Overview

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Overview Product description and type designation PTZ camera for marine onshore/offshore or industrial applications. The Esprit Anti-Corrosion Enhanced 1 Series, PTZ is resistant to rust and corrosion and does not require maintenance thanks to the absolute precision of the construction process and the solid AISI 316L stainless steel construction with micro-shot and electropolished surfaces.
  • Page 10: Model Identification

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Never, under any circumstances, make any changes or connections that are not shown in this handbook. Improper use of the appliance can cause serious hazards, risking the safety of personnel and of the installation.
  • Page 11: Safely Disposing Of Packaging Material

    Preparing the product for use Any change that is not expressly approved by the manufacturer will invalidate the warranty. Product Package Contents Ensure the product package contains the following: Pelco Esprit Anti-Corrosion Enhanced 1 Series, PTZ Camera Sunshield Bolts and screws Wash system kit...
  • Page 12: Installation Steps

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Screws capable of bearing 4 times the weight of the unit (for securing the ceiling mount). Screws and fixing devices capable of bearing 4 times the weight of the unit (for securing the wall mount).
  • Page 13: Installing The Housing Sunshield

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Figure 3: Loosen the screws . Remove the optical kit taking care not to damage the flat cables. Figure 4: Optical kit removal. Insert the memory card into the slot as indicated. Pay attention to the direction of the memory card. Figure 5: Memory card insertion.
  • Page 14: Mounting In The Correct Orientation

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Figure 6: Installing the housing sunshield. Mounting in the Correct Orientation The system can be installed only in a standard or inverted position (ceiling mount). When installed for inverted operation, the camera orientation and controller functions are reconfigured for normal operation through the system’s software.
  • Page 15 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Fix the bracket (01) to the bottom of the unit using the 4 flat countersunk screws (02) with hexagonal socket M10x20mm in stainless steel (A4 class 70) supplied with the bracket. Make sure the thread are free of dirt and debris. Apply a generous amount of thread locking compound (Loctite 270) into the threaded holes in the base of the device.
  • Page 16: Fixing With Wall Mount Bracket

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Fixing with wall mount bracket Fasten the device to the bracket by using 4 flat washers, 4 serrated stainless steel washers and 4 stainless steel hex head screws (A4 class 70) M10x20mm supplied with the bracket. Make sure the thread are free of dirt and debris.
  • Page 17: Fixing The Unit To The Pole Mount Adapter Or Corner Mount Adapter

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Figure 11: Wall mount drilling pattern. Fixing the unit to the pole mount adapter or corner mount adapter The adapter can be fixed to a pole or a vertical wall. Use a pole or screws that can bear at least 4 times the weight of the unit.
  • Page 18: Cable Connections

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Pay attention to the fixing. Tightening torque: 35Nm. The thread compound must cure for one hour, allow for this period prior to completing the installation. Figure 13: Fasten the support bracket. To fix the device to the bracket, consult the relevant chapter (Fixing with wall mount bracket).
  • Page 19: Ethernet Cable Connection

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual CONNECTING THE POWER SUPPLY Cable colour Description Power supply 24Vac Black 2 (N) Neutral Black 1 (L) Phase Yellow/Green Safety earth Power supply 220-230Vac Black 2 (N) Neutral Black 1 (L) Phase Yellow/Green Safety earth Power supply 120Vac...
  • Page 20: Connecting An Alarm With Dry Contact

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual ALARMS AND RELAYS CONNECTIONS Cable colour Description Green Common alarm, COM Brown Alarm 1 (dry contact), AL1 White-Yellow Reset input power supply Black Reset input Table 3: Alarms and relays connections. Electrically insulate all cables not connected or not listed on the table. Connecting an alarm with dry contact For a dry contact alarm (alarm AL1), implement the connection as shown in the figure.
  • Page 21: Washing System Connection

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Washing system connection For further details on configuration and use, refer to the relative manual. When the washing system is enabled, the relay 2 reports the pump activation (Alarms and relays connections). About the configuration please refer to the relative manual (Configuring the Camera).
  • Page 22: Assigning An Ip Address

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Assigning an IP Address The device automatically obtains an IP address when it is connected to a network. If the device cannot obtain an IP address from a DHCP server, it will use Zero Configuration Networking (Zeroconf) to choose an IP address.
  • Page 23: Maintenance

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Maintenance Before doing any technical work on the device, disconnect the power supply. Caution:Device installation and maintaining must be performed by specialist technical staff only. The manufacturer declines all liability for damage to any of the apparatus mentioned in this handbook, when resulting from tampering, use of non-original spare parts, installation, maintenance and repairs performed by non-authorised, non-skilled personnel.
  • Page 24 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Figure 15: Cover removal. The new fuses must comply with the directions given in the table. FUSES REPLACEMENT Supply voltage Fuse (F1) Fuse (F2) T 4A H 250V 5x20 24Vac, 50/60Hz T 4A H 250V 5x20 T 4A H 250V 5x20 120Vac, 50/60Hz T 2A H 250V 5x20...
  • Page 25: Cleaning

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual At the end of the operations close the product. Pay attention to the fixing. Tightening torque: 1.5Nm (±0.2Nm). Cleaning Frequency will depend on the type of environment in which the product is used. Cleaning of the window and external surfaces of the product Avoid ethyl alcohol, solvents, hydrogenated hydrocarbide, strong acid and alkali.
  • Page 26: Technical Drawings

    Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Technical drawings The indicated measurements are expressed in millimetres. Figure 17: Esprit Anti-Corrosion Enhanced 1 Series, PTZ. MNLCNXPTZ2_2240 | 11/22...
  • Page 27 Esprit Anti-Corrosion Enhanced 1 Series, PTZ Installation Manual Pelco, Inc. 625 W. Alluvial Ave., Fresno, California 93711 United States (800) 289-9100 Tel (800) 289-9150 Fax +1 (559) 292-1981 International Tel +1 (559) 348-1120 International Fax www.pelco.com Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pelco, Inc.