Menu Structure - Bosch Control 8310 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Menu structure

10
Menu structure
The control unit has 2 menu levels, in which system-dependent settings
are made. The levels and parameters displayed depend on the modules
installed and the factory defaults. The parameters that are not required
for the selected function are not displayed.
Parameters that are not active are highlighted in grey in the display.
Operation of the control unit and the installed modules is performed via
the master control unit. The functions of the most frequently used
modules FM-MM and FM-MW are described in the instructions of the
master control unit.
The fundamental operation and calling up of the menus with the control
unit via the master control unit is described in chapter 3 from page 5.
▶ Observe operating instructions.
Main menu
Explanation/Function
General characteristic
Settings of the control unit, of heating system parameters and the house properties
data
Module configuration
For selecting whether modules are detected and installed automatically or manually
Heat production
Settings of the boiler data, depending on the heat source.
This can only be displayed and set if a function module FM-AM is installed.
Heating circuit data
Setting of different heating circuit data (e.g. heating circuit system, maximum flow temperature)
and display of current heating curves of the relevant heating circuit
Domestic hot water
Water treatment settings
Reset
Restore the factory settings in the main menu and in the service menu.
Control unit
Save or load configurations.
Connectivity
Activation and setting of network connection
Function test
Check whether system components (e.g. pumps) are correctly connected.
The displays depend on which modules are installed. Depending on the operating conditions,
there may be a time delay between the demand and display.
Lock screen
Option for blocking the screen.
Monitor data
Shows set values and actual values of the system. Tap the symbol
values.
Fault
Displays the faults in the heating system. The remote control of the master control unit displays
the faults of the control unit to which it is linked, or is selected via the networking.
Table 4 Main menu
12
To open the service menu:
▶ Press and hold the symbol
5 seconds.
The service menu overview containing the symbols for the available
functions appears.
To set parameter:
▶ Tap corresponding symbol.
▶ Make settings.
In the following tables the factory settings are highlighted in bold in the
"Settings/Adjustment range" column.
in the footer to call up the
( Fig. 2, [7], page 6) for roughly
Further information
 Chapter 10.1, page 13
 Chapter 10.2, page 13
 Description of the
master control unit
 Description of the
master control unit
 Chapter 12, page 15
 Chapter 13.2, page 16
 Chapter 11, page 14
 Description of the
master control unit
 Description of the
master control unit
 Description of the
master control unit
 Description of the
master control unit
 Chapter 13.6, page 16
Control 8310 – 6720856493 (2022/07)

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents