Power supply wire and ground wire connection

Connecting the power supply wire and the ground wire
(1) Remove 3 cover fixing screws pointed to by arrows and open the cover.
(2) Insert cross notches in the rubber bushing in order to pass the power supply cable.
(3) Pass the power supply cable through the rubber bushing and the clamp, and connect the power supply wire and the
ground wire to the specified terminal block.
(4) Close the cover and secure with 3 cover fixing screws.
Cover fixing screw
Cover fixing screw
Power supply cover
[REQUIREMENT]
• Do not connect the device directly to the primary side of the power supply.
• Be sure to install a circuit breaker or earth-leakage breaker on the primary side of the power supply.
• Fasten the screws to the terminal block with torque of 0.5 N·m.
Screws indicated by arrows
Rear side terminal block
Power terminal
(Put back the transparent
cover after attaching the
power supply wire.)
Power supply wire
(Securely fix the cable with
a clamp.)
5 mm
Clamp
18 mm
9
32RCA001TS-02ISEN
RS485 terminating resistor setting switch
Ground wire
Ground terminal
Rubber bushing