Balance Mechanism Digital Display Calibration - Vinten Vision 100 Operator's Manual

Pan and tilt head
Hide thumbs Also See for Vision 100:
Table of Contents

Advertisement

Balance mechanism digital display calibration

The digital display
(14)
ting) to HI (maximum setting). In the unlikely event of this system requiring calibration, proceed as
follows:
Level the platform and apply the tilt brake (7).
Turn the balance knob
NOTE:
If more than 15 seconds is allowed to elapse between steps, the system will
shut down and revert to its previous settings.
1 Press and hold the switch
display shows CA.
2 Release the switch (13). The display shows HI.
3 Ensure balance knob
press and release the switch (13). The display will now show LO.
4 Turn the balance knob
and release switch (13). If the calibration is successful, the display will now show 00.
5 If unsuccessful, Er will be displayed. Pressing the switch
15 seconds, will allow the system to revert to its previous settings. Calibration may
now be carried out again.
After calibration, rebalance the head
2
3
4
5
Balance mechanism digital display calibration
indicates setting of the balance mechanism on a scale of 00 (minimum set-
(16)
fully clockwise to its maximum stop.
(13)
for approximately eight seconds, until the digital
(16)
is turned fully clockwise to its maximum stop, then
(16)
fully counter-clockwise to its minimum stop. Press
(See Balancing the
1
head).
(14)
(16)
(13)
again, or waiting for
(13)
17