Balance mechanism digital display calibration

The digital display
(14)
ting) to HI (maximum setting). In the unlikely event of this system requiring calibration, proceed as
follows:
Level the platform and apply the tilt brake (7).
Turn the balance knob
NOTE:
If more than 15 seconds is allowed to elapse between steps, the system will
shut down and revert to its previous settings.
1 Press and hold the switch
display shows CA.
2 Release the switch (4). The display shows HI.
3 Ensure balance knob
and release the switch (4). The display will now show LO.
4 Turn the balance knob
release switch (4). If the calibration is successful, the display will now show 00.
5 If unsuccessful, Er will be displayed. Pressing the switch
15 seconds, will allow the system to revert to its previous settings. Calibration
may now be carried out again.
After calibration, rebalance the head
2
3
4
5