Digital Onboard Inputs; Fig. 7-12: Digital Inputs - Bosch Rexroth IndraControl L40 Project Planning Manual

Table of Contents

Advertisement

7-8
Connections and Interfaces

Digital Onboard Inputs

IAS COMPONENTS www.ias-components.com info@ias-components.com
The left-hand section of the plug panel provides eight digital inputs as
onboard inputs.
Slots 1 and 2:
Fig. 7-12:
Digital inputs
Note:
Observe the color-coding of the connectors.
Number of inputs
Connection method
Electric isolation from U
S
Electric isolation from U
L
Reverse voltage protection
Input voltage:
Nominal value at "0"
Nominal value at "1"
Input current:
Nominal value at "0"
Nominal value at "1"
Delay time:
If "0" to "1"
If "1" to "0"
Current consumption by 24-V supply (U
Cable length (unshielded)
Interrupt inputs
Sensor supply
Output voltage
Nominal current (total)
Short-circuit protection, overcurrent protection Typ. 0.6 A
IndraControl L40
8
2-wire connection
No
Yes
Yes
–3 V ... + 5 V
11 V ... 30 V
< 2.5 mA
2.8 mA ... 6 mA
Typ. 50
s
µ
Typ. 50
s
µ
)
Typ. 60 mA
S
< 100 m
8
From U
via a PTC fuse
S
Typ. Uext. – 1V
0.2 A
DOK-CONTRL-IC*L40*****-PR02-EN-P
Eingänge.FH9