Table of Contents

Advertisement

Quick Links

Original
Instruction Manual
Version A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Verisight Pro+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Envirosight Verisight Pro+

  • Page 1 Original Instruction Manual Version A...
  • Page 3 Specifications, dimensions and other statements in this document are subject to change without prior notice. Envirosight LLC and its suppliers shall not be liable for any damages related to this software or hardware, or for any other damages whatsoever caused by the use of or inability to use any Envirosight product.
  • Page 4: Table Of Contents

    CONTENTS WARRANTY TEXT CONVENTIONS Danger, Caution and Note ..............12 Bold Font .....................12 Lists .....................12 Menu Selections ..................12 PRODUCT DESCRIPTION EC DECLARATION OF CONFORMITY CE Declaration ..................14 SYSTEM OVERVIEW WARNINGS, SAFETY MEASURES AND CARE Before first use ..................18 Maintenance ................20 Cleaning ..................21 General cleaning work ..............21 Preparing the CCU for First Use ............
  • Page 5 Environmental Operating Temperature Consideration ......30 DISPLAY FEATURES Introduction ..................31 Status Icons ..................33 Internal Memory ................ 33 SD/MMC Card Memory ............. 33 External USB Memory ..............33 Internal and External Battery Status ..........34 Display Brightness ..............35 KEYBOARD SURVEY KEYS Distance .....................
  • Page 6 To view files contained inside the Daily Directory ......49 To select one of the files for viewing .......... 49 Show/Play Function ................50 Copy function ..................50 Rename Function .................51 Delete function ..................51 Un-mounting external memory ............52 USB / SDHC Media Types ..............52 Camera Keys ..................
  • Page 7 Time and Date ..................64 Camera / External Monitor ..............64 External Monitor ................ 64 Color Level ................. 65 Brightness .................. 65 Hue ................... 65 Contrast ..................65 Power Saving ..................66 Camera and LCD Dimming ............66 Automatic Shutdown ..............66 SONDE Survey ....................
  • Page 8 Information and Care................88 Pressurization ................88 Cleaning ..................88 Maintenance ................88 Technical Details CAM025 ..............89 CAM026 – PAN-AND-TILT CAMERA MODULE Connections and Descriptions ..............91 PAN-AND-TILT CAMERA OPERATION AND CONTROL Basic camera operation ............... 92 Home ..................92 Check Pressure................
  • Page 9 WINCAN EMBEDDED REPORTING SOFTWARE To start WinCan Embedded Reporting Software ...... 100 Comments Form ..............101 Start Recording .................101 Adding a New Observation ............101 Review Survey ................101 End Survey ................102 Export to WinCan ..............102 WEEE STATEMENT PRODUCT SERIAL NUMBERS USEFUL INFORMATION...
  • Page 11 ANY COMPONENTS WHICH HAVE BEEN SUBJECT TO ACCIDENT, NEGLIGENCE, ALTERATION, ABUSE, UNAUTHORIZED REPAIR, OR OTHER MISUSE. NOTE: In the event that equipment cannot be returned to Envirosight, for whatever reason, the customer agrees to pay for all travel and living expenses incurred to have an Envirosight representative evaluate, assess or affect a field warranty repair.
  • Page 12: Text Conventions

    Tools > Power Saving > Automatic Shutdown > OK This example describes pressing the Tools key and selecting the Power Saving option, then Automatic Shutdown, and finally pressing the OK key. Envirosight Verisight Pro + Version A...
  • Page 13: Product Description

    5.9 inches (150mm) diameter. Built using high quality materials and state-of-the-art technology the Verisight Pro+ inspection system is a robust and powerful tool for use in harsh environments. Envirosight Verisight Pro + Version A...
  • Page 14: Ec Declaration Of Conformity

    EC Declaration of Conformity CE Declaration We Envirosight LLC. 111 Canfield Ave., Unit B3, Randolph, NJ 07869 hereby de- clare that the product Verisight Pro + to which this declaration refers is in compliance with the following standards or standardizing documents: EN61000-6-2:2005 Generic standards –...
  • Page 15: System Overview

    System Overview The inspection system Verisight Pro+ consists of the following main components: • CCU • Coiler • Camera A typical configuration is shown in this illustration: Envirosight Verisight Pro + Version A...
  • Page 16: Warnings, Safety Measures And Care

    Verisight Pro+ inspection system and its components. CAUTION! The operator of the Verisight Pro+ inspection system must be trained by either Envirosight or one of its authorised representatives before using the system. CAUTION! Despite all of the safety functions built into the system, the operator is not exonerated in any way from his/her duty of care.
  • Page 17 DANGER! Risk of deadly injuries from electrical current! Only the power supply supplied as part of the Verisight Pro+ inspection system can be used and should NOT be replaced by any other. Envirosight Verisight Pro + Version A...
  • Page 18: Before First Use

    If you find cable damage, immediately disconnect the power supply and inform the appropriately trained staff or Envirosight Service Center. • Work on the electronics, which are not covered in this document, shall only be carried out by trained specialist staff or an Envirosight Service Center.
  • Page 19 • Only use the inspection system for work that is appropriate to the specifications. • Observe the operational requirements for this inspection system as described in this user manual. • Keep the system clean. Observe the individual cleaning instructions for this purpose. Envirosight Verisight Pro + Version A...
  • Page 20: Maintenance

    The specific maintenance work steps will also be explained. NOTE! The operator of the system is responsible for the proper disposal! See information on page 103 on the return of equipment at the end of the useful life. Envirosight Verisight Pro + Version A...
  • Page 21: Cleaning

    Ensure that no fluids can enter the control panel or penetrate the housing of the cable reel. If this happens, immediately disconnect the power supply and inform the Envirosight Service Center. CAUTION! Risk of fatal injuries caused by electrical current! For all cleaning and maintenance work disconnect the system from the power supply.
  • Page 22 Envirosight Verisight Pro + Version A...
  • Page 23: Preparing The Ccu For First Use

    Pipeline Inspection System. If the contents of the accessory case are incomplete or if the Verisight Pro+ Pipeline Inspection System does not operate as you would expect, notify Envirosight or your nearest Envirosight Service Center. If the shipping container is damaged or the cushioning material shows signs of stress, also notify the carrier.
  • Page 24 ON indefinitely with no ill effects. CAUTION! Never plug the control unit into a power supply source that is more than 12 volts DC nominal. Failure to ignore this will result in system damage. Envirosight Verisight Pro + Version A...
  • Page 25: Attaching The Ccu To The Coiler

    The unit does not need to be installed on the coiler to operate. It can be operated stand alone for setting up, viewing recorded surveys and generating reports. It only needs to be installed on a coiler when actually performing a survey. Envirosight Verisight Pro + Version A...
  • Page 26: Ccu210 - Control Unit

    USB or SD card. The control unit can generate on screen text that is overlaid onto the recorded video in various colors and positions, allowing easy customization. Envirosight Verisight Pro + Version A...
  • Page 27: Ccu Overview

    3 Video Output 11 Survey Keys 4 Joystick 12 Special Function Keys 5 Cursor Control Keys 13 Multi-function “Hot” Keys 6 Special Function Keys 14 Protective Flap for USB or 7 Camera Keys SD Card Envirosight Verisight Pro + Version A...
  • Page 28: Rear View

    Rear view 1 Carry Handle 2 Lid Fastener Clip 3 Coiler Input 4 PSU (Power Supply Unit) Input Envirosight Verisight Pro + Version A...
  • Page 29: Switching The Ccu On

    Initialized When the Verisight Pro + control unit has initialized the green colored LED indicator stops flashing and is permanently illuminated, and the Envirosight splash-screen will show on the LCD display. When the splash-screen disappears you will be asked to press OK to acknowledge that you are familiar with the operational requirements of the equipment.
  • Page 30: Switching The Ccu Off

    NOTE ! Using the equipment in direct sunlight can cause the electronics to overheat and shut-down unexpectedly. The equipment will not turn on again until it has been allowed to cool down. Envirosight Verisight Pro + Version A...
  • Page 31: Display Features

    This is free text and is used to annotate the survey and is recorded with the video picture. The color and position of this text may be controlled with dedicated keys on the keypad. Envirosight Verisight Pro + Version A...
  • Page 32 If Power Saving is enabled (see page 66), the screen backlight intensity will automatically reduce to a low level if the keypad is not used for a pre-set time period, returning to its normal intensity when any key is pressed. Envirosight Verisight Pro + Version A...
  • Page 33: Status Icons

    The used proportion of the USB memory is shown as the uncolored bars at the top of the gauge, and the available portion is shown as the colored bars at the bottom of the gauge. Envirosight Verisight Pro + Version A...
  • Page 34: Internal And External Battery Status

    When connected to an external power source, the battery icon is replaced with a power plug icon and when the battery is charging a lightning strike symbol appears to the right of the icon. Envirosight Verisight Pro + Version A...
  • Page 35: Display Brightness

    Press F1 (Red key) for Internal or F2 (Blue key) for External Press F5 (Magenta key) to display the LCD Backlight status bar Use the Left Arrow cursor key to decrease the brightness or the Right Arrow cursor keys to increase the brightness. Envirosight Verisight Pro + Version A...
  • Page 36: Keyboard

    12 Sonde Activation Key (page 75) 5 Camera Keys (see page 53 ) 13 Screens Key (page 74) 6 Joystick (see page 56 ) 14 Cursor Keys (see page 57) 7 Caps Lock Key Envirosight Verisight Pro + Version A...
  • Page 37: Survey Keys

    Hide F4 (Green key ) Hides or shows the distance from the display. Color F5 (Magenta) Change the color and/or outline of the screen text. Units F6 (Cyan) Set the units of measure: 0.00’/ 0’.0”/0.00m/0.00cm. Envirosight Verisight Pro + Version A...
  • Page 38: Text

    Hides/shows the distance from the display Clock F5 (Magenta key) Hides/shows the clock from the display Move F6 (Cyan key) Use the cursor control Left Arrow, Up Arrow, Right Arrow and Down Arrow to reposition the on-screen text. Envirosight Verisight Pro + Version A...
  • Page 39: Survey Folder

    Survey Folder The Survey Folder key is used to start a ProPipe survey (see page 96) or a WinCan survey (see page 100). Envirosight Verisight Pro + Version A...
  • Page 40: Recording And Playback Keys

    These keys control the recording and playback of video files 1 Rewind 2 Start 3 Fast Forward 4 Pause 5 Stop 6 Snapshot 7 Record The keys shown above are described in more detail on the following pages. Envirosight Verisight Pro + Version A...
  • Page 41: Recorder Control Keys

    In the center bottom of the screen, a progress bar is displayed to show the current position in the total length of the recorded file. To the right of this is the total Envirosight Verisight Pro + Version A...
  • Page 42: Fast Forward

    1.5, pressing a second time will increase the zoom ratio to 2 and pressing a third time will increase it to 3. Pressing this key a fourth time returns the picture to normal view. Envirosight Verisight Pro + Version A...
  • Page 43: Snapshot Capture

    Snapshots may be taken while recording or playing back a survey. If a snapshot is taken while the picture is zoomed in (see page 42), then it will be the zoomed image which is stored as the snapshot. Envirosight Verisight Pro + Version A...
  • Page 44: Media Keys

    CCU or on external storage using a USB stick or SD Card. 1 Press the Data Storage key. The dialogue will show the internal memory of the CCU plus any mounted external memory eg: SD Card and/or USB Stick. Envirosight Verisight Pro + Version A...
  • Page 45 Then manually remove the SD Card or USB stick from its slot. Explore Select Explore to view all stored video and data files. Erase All Select Erase to erase all stored video and data files. Envirosight Verisight Pro + Version A...
  • Page 46: Media Browser

    1 Internal memory - usually used to record video surveys. 2 USB memory - usually a memory stick plugged into the front panel connector. 3 SD card memory - an SD card inserted into the front panel slot Envirosight Verisight Pro + Version A...
  • Page 47 The memory types are shown in the gallery in the following way:- The tick next to one of the memory types shows which one is selected for viewing and where the video files are automatically recorded to. Envirosight Verisight Pro + Version A...
  • Page 48: To Change The Selected Memory Type

    The daily directories or video files in the selected memory type are then displayed in the order in which they were recorded (most recent at the top of the list). Envirosight Verisight Pro + Version A...
  • Page 49: To View Files Contained Inside The Daily Directory

    NOTE: If the selected file is a .jpg picture, then the first menu entry is Show and if the selected file is an .mp4 or .avi movie file, then the first menu entry is Play. Envirosight Verisight Pro + Version A...
  • Page 50: Show/Play Function

    If copying all files you will now be prompted to press Y to confirm copying all files. A progress bar will show the status of the transfer. When you are copying multiple files the system will show you overall progress and individual file progress on two separate progress bars. Envirosight Verisight Pro + Version A...
  • Page 51: Rename Function

    Y key. NOTE: The Delete function may take a short time to execute so to show how much of the function has been completed a progress bar is displayed on the screen. Envirosight Verisight Pro + Version A...
  • Page 52: Un-Mounting External Memory

    USB / SDHC Media Types Due to variations in USB / SD Flash media technology, Envirosight cannot guarantee that all types and sizes will function correctly. For USB we recommend a read speed of a least 15MB/s and a write speed of a least 8MB/s.
  • Page 53: Camera Keys

    If the survey picture is zoomed in during a recording then the zoomed view will be recorded together with the red on white symbol to show which area of the survey picture is being viewed. Envirosight Verisight Pro + Version A...
  • Page 54: Camera Sweep

    Press the Illumination key. The Camera Illumination status bar will be displayed. Use the cursor control Left Arrow key to decrease the illumination. Use the cursor control Right Arrow key to increase the illumination. Envirosight Verisight Pro + Version A...
  • Page 55: Home

    Home Press the Home key. The camera head returns to the home position. Focus Press the Plus key or Minus key. adjust the sharpness of the image on screen. Envirosight Verisight Pro + Version A...
  • Page 56: Joystick

    The functions of the joystick are as follows: Move the joystick Left or Right to perform an 360° endless rotation of the camera. Move the joystick Up or Down to pan the camera 135° + or - (Plus or Minus). Envirosight Verisight Pro + Version A...
  • Page 57: Cursor Control Keys

    The cursor control consists of five keys; Left Arrow, Up Arrow, Right Arrow, Down Arrow and OK. These five keys are used to move the cursor around the screen after entering text and to move around and highlight menus in the gallery and set-up menus. Envirosight Verisight Pro + Version A...
  • Page 58: Function Keys

    The colors of the keys are referred to in this manual as shown below: F1 Red key F2 Blue key F3 Yellow key F4 Green key F5 Magenta key F6 Cyan key Envirosight Verisight Pro + Version A...
  • Page 59: Special Keys

    Press the Symbols key and the Symbols menu will be displayed. The functions of this menu are described on page 76. Help Key Press the Help key and the Help menu will be displayed. The functions of this menu are described on page 80. Envirosight Verisight Pro + Version A...
  • Page 60: Tools (Setup And Configuration)

    To Display the Setup menu 1 Press the Tools key. The Setup and Configuration menu will be displayed. A map of the above menu is shown on the next page. Envirosight Verisight Pro + Version A...
  • Page 61 Power Saving >Camera and LCD Dimming >Automatic Shutdown Sonde >Frequency Survey >ProPIPE >WinCan WiFi Software Update >Software Update Browser Service Center Each of the setup functions will be described in detail on the following pages. Envirosight Verisight Pro + Version A...
  • Page 62: Files And Formats

    Example filename: 160930_1059-Envirosight.avi This indicates that the file was recorded on the 30th September 2016 and started at 10:59. Envirosight is the default filename and .avi shows that the file is in the motion video AVI format Video File Format...
  • Page 63: Theme

    This feature allows the user to install or view currently installed licences on the Verisight Pro+. Certain features require a licence to be installed to activate them i.e. ProPIPE Report and WinCan. Select the required View or Install option: Envirosight Verisight Pro + Version A...
  • Page 64: Time And Date

    This is an optional extra (purchased separately) on Verisight Pro+. If installed you can turn the video output ON/OFF by selecting this option. When ON a green tick sits alongside this option to signify that it is active. Envirosight Verisight Pro + Version A...
  • Page 65: Color Level

    Adjusts the Contrast of the picture. Press the Left Arrow or Right Arrow cursor key to change the setting. Press ‘0’ to reset to default setting. These settings do not affect the display of the menus on the screen, only the video from the camera is affected. Envirosight Verisight Pro + Version A...
  • Page 66: Power Saving

    When the Verisight Pro+ is powered only by internal batteries this feature will power down the Verisight Pro+ after a period of inactivity. The options are: Never / 5 / 15 / 60 minutes. Envirosight Verisight Pro + Version A...
  • Page 67: Sonde

    2 Select the required Sonde frequency from the drop-down menu. The Sonde frequency options are: 512Hz / 640Hz / 33KHz The Sonde frequency can also be set using the Sonde Key see page 75. Envirosight Verisight Pro + Version A...
  • Page 68: Survey

    1 Select Survey from the Setup and Configuration drop-down menu (see page 60). 2 Select the required software: ProPIPE or WinCan. 3 Select the required option eg: Survey Take Snapshot Picture. 4 Select the required option. eg: Always take snapshot Envirosight Verisight Pro + Version A...
  • Page 69: Wifi

    1 Select WiFi from the Setup and Configuration drop-down menu page 60. 2 A menu will be displayed giving options to connect to WiFi. 3 Select Stored F3 (Yellow Key) to view stored network URLs (addresses). Envirosight Verisight Pro + Version A...
  • Page 70 4 Select Find WiFi... F1 (Red Key) to search for available networks. 5 Select the required network form the menu. 6 Select Connect F1 (Red Key) to connect to the selected network. Envirosight Verisight Pro + Version A...
  • Page 71 8 The main display screen (see page 31) shows the WiFi status icon at the bottom right-hand side of the sidebar. WiFi NOT CONNECTED Red cross indicates no signal WiFi CONNECTED Vertical blue colored bars indicate signal strength Envirosight Verisight Pro + Version A...
  • Page 72: Software Update

    1 Select Software Update from the Setup and Configuration drop-down menu page 60. The Software Updates Browser will be displayed. 2 Select the removable media you are using and press OK. Highlight the update you want to install and press OK. Envirosight Verisight Pro + Version A...
  • Page 73: Service Center

    40% charged. This feature will then appear greyed out in the menu. Service Center This menu option is for sole use by Envirosight and its authorized dealers. As such, this option is password protected. Envirosight Verisight Pro +...
  • Page 74: Screens Key

    Select Internal or External Press F1 (Red key) to display the LCD Backlight status bar Use the Left Arrow cursor key to decrease the brightness or the Right Arrow cursor keys to increase the brightness. Envirosight Verisight Pro + Version A...
  • Page 75: Sonde Key

    The Sonde can be cycled through three states – OFF, PULSED, ON. A symbol is displayed in the sidebar of the main screen indicating the current status and frequency of the Sonde: 1) OFF 2) PULSE ON/OFF 3) ON Envirosight Verisight Pro + Version A...
  • Page 76: Symbols Key

    To add Arrows go to Step 4 To add Wide Ovals, Tall Ovals and Squares repeat 2 (above) selecting the required shape. To add Clock Faces go to Step 6 To add Text Symbols go to Step 9 Envirosight Verisight Pro + Version A...
  • Page 77 Press OK. The shape will be displayed on screen. 4 To add arrows, use the Up Arrow keys and Down Arrow cursor keys to highlight the arrow direction you require. Press OK. Envirosight Verisight Pro + Version A...
  • Page 78 Press OK. 7 Use the Up Arrow keys and Down Arrow cursor keys to highlight in yellow the “time” of clock face you require. Press OK. Envirosight Verisight Pro + Version A...
  • Page 79 Down Arrow. When the desired position is located press OK to set the position. NOTE! After pressing OK to position the graphic, it cannot be moved. The graphic will need to be erased and a new graphic created. Envirosight Verisight Pro + Version A...
  • Page 80: Help Key

    1 Press the Help key The help menu will be displayed: Press F1 (Red key) to go to the “How To” Videos Image for illustration purposes only. Subject to change as videos are added to the system. Envirosight Verisight Pro + Version A...
  • Page 81 Press F3 (Yellow key) to go to the Camera Help which will show the camera pressure: Press F5 (Magenta key) to go to the Keyboard Help which will show the following menu from which to select a category: Envirosight Verisight Pro + Version A...
  • Page 82: Coiler

    Coiler The coiler supplied with the Verisight Pro+ system features Envirosight’s unique bullhorn shaped top section, enabling quick and easy fitting of the CCU to the coiler (see page 25). Available with rod lengths of 130ft, 200ft and 330ft, the coiler also features a Friction Brake (see page 84) and has a Coiled Link Cable with protective dust cover.
  • Page 83: Connections And Descriptions

    3 CCU Location Pins. 4 Friction Brake. 5 Self-Leveling Axial camera - CAM025 (see opposite) NOTE! The CCU can power the coiler without the use of External Charger SPP-PSU or Proteus Battery Pack BPP24. Envirosight Verisight Pro + Version A...
  • Page 84: Friction Brake

    Using the friction brake is a simple one handed operation with 3 options:. 1 The brake can be fully locked 2 The brake can be unlocked 3 The brake can applied as a friction brake to avoid unwanted pay-off of the rod. Envirosight Verisight Pro + Version A...
  • Page 85 Cleaning agents or solvents must not be used. These can damage the seals and other materials on the system. Only clean water should be used. Envirosight Verisight Pro + Version A...
  • Page 86: Technical Details - Verisight Pro+ 130Ft Coiler

    Construction: Welded Steel Finish: Powder Coated Distance Counter Units: Feet, Meters Controls: Friction Brake Weight: (66lb) 30kg Dimensions (L x W x H): 31.4 x 14.5 x 39.3 inches /l80 x 37 x 100cm Envirosight Verisight Pro + Version A...
  • Page 87: Cam025 - Self Leveling Axial Camera

    • Illumination intensity adjustable to 12.5K lux at 150mm • Pipe compatibility 2in (50mm) and up The camera module is pressure-tight up to 1bar. It is suitable for inspections up to 32ft water depth. Envirosight Verisight Pro + Version A...
  • Page 88: Connections And Descriptions

    Ensure the camera module is thoroughly cleaned after each inspection. Ensure the connectors are free from dirt and moisture. Always fit the protective cap immediately after disconnecting the camera module from the system. Maintenance Ensure that the camera connector is free from dirt. Envirosight Verisight Pro + Version A...
  • Page 89: Technical Details Cam025

    Sensitivity: <1.0 lux Aperture: FOV: F2.5 / 75° Power Consumption: Weight: 1.29lb (589g) Temperature Range: -4° ~ +122°F (-20°C ~ +50° C) Environmental Protection: Pressurized Internal Pressure: 0 to 500mBar ATEX Rating: Zone 2 Envirosight Verisight Pro + Version A...
  • Page 90: Cam026 - Pan-And-Tilt Camera Module

    • Motorized focus control • Internal pressure monitoring • Impact resistant with user replaceable rubber protectors The camera module is pressure-tight up to 1 bar. It is suitable for inspections up to 32ft water depth. Envirosight Verisight Pro + Version A...
  • Page 91: Connections And Descriptions

    Connections and Descriptions 1 Camera connector 2 Serial number location 3 LED illumination 4 Camera lens 5 Rubber protector 6 Rubber protector 7 Camera protection skid 8 Camera protection skid screws (x6) Envirosight Verisight Pro + Version A...
  • Page 92: Pan-And-Tilt Camera Operation And Control

    +/-45 degrees of horizontal. Otherwise it is unaware of which way is up! If the camera fails to home check the camera body position. Likewise the auto-level feature will only work up to +/-45 degrees from horizontal. Envirosight Verisig ht Pro+ Version A...
  • Page 93: Check Pressure

    (opposite) to get the camera working first. 1 Move the camera with the joystick to allow easy access to the valve on the side. 2 Unscrew the protection cap from the camera and screw in the recharge valve. Envirosight Verisig ht Pro+ Version A...
  • Page 94: Driving The Camera With Pre-Set Movements

    360° clockwise or anti-clockwise. To view the full range of pre-set movements press the Camera Sweep Key and select Go from the menu. Highlight the required movement and press OK to activate it. Envirosight Verisight Pro + Version A...
  • Page 95: Information And Care

    Dimensions: 4.7 x 2.8 x 2.8 inches (L x W x H) Power Consumption: Weight: (1.87lb) 0.85Kg Temperature Range: -4° ~ +122°F (-20°C ~ +50° C) Environmental Protection: Pressurised Internal Pressure: 0 to 500mb Envirosight Verisight Pro + Version A...
  • Page 96: Propipe Reporting Software

    Down Arrow keys. 7 Press OK to select. NOTE! This will only change the color on the selected line which the arrow is pointing to, you need to repeat for each individual line of text. Envirosight Verisight Pro + Version A...
  • Page 97: Hiding Lines Of Information

    12 Press the Survey Forms key which will automatically pause the recording. 13 Select New Observation from the menu. 14 Press OK. 15 Input your required text into the box which appears on-screen. 16 Press the Survey Forms key to store the observation. Envirosight Verisight Pro + Version A...
  • Page 98: Continuing A Survey

    Play key. You can now skip to each defect by pressing the Arrow Up or Arrow Down keys. Create Report 28 At this stage press the Y key to create a report, or press the Esc key to create a report later. Envirosight Verisight Pro + Version A...
  • Page 99 Transfer this to your memory stick by using the copy function, as you would do with any other file. Once on your memory stick you can plug this into a PC where you can then open up the Word document containing your completed survey. Envirosight Verisight Pro + Version A...
  • Page 100: Wincan Embedded Reporting Software

    NOTE! this will only change the color on the selected line which the arrow is pointing to, you need to repeat for each individual line of text. 6 Once you have input all your information press OK. This brings you to the Comments Form. Envirosight Verisight Pro + Version A...
  • Page 101: Comments Form

    13 At any time you can review your survey. Press the Survey Folder key and select Review Survey. This will show you each observation you have entered with the distance displayed along the captured image. Envirosight Verisight Pro + Version A...
  • Page 102: End Survey

    (ie: highlight USB) and press OK. Then you select the option Merge to USB and press OK. A prompt will appear saying press Y to confirm. Press Y and merging will commence. Once finished a box will appear informing you that merging has finished. Envirosight Verisight Pro + Version A...
  • Page 103: Weee Statement

    Envirosight will comply with the product take back requirements at the end of life of Envirosight products that are sold into the EU. For disposal contact Envirosight or the Envirosight Partner in your country.
  • Page 104 Enter your product serial numbers below for future reference: COILER CAM025 Self Leveling Axial CAM026 Pan & Tilt Useful Information Telephone 866-936-8476 973-252-6700 Customer Service: Marie Weinberg 973-252-6700, marie@envirosight.com Technical Support: James Nystrand 973-252-6700, jnystrand@envirosight.com Order Status: Tammy Smith 973-252-6700, tammy@envirosight.com...
  • Page 105 Notes...
  • Page 106 Notes...
  • Page 107 Notes...
  • Page 108 ©Copyright 2016 Envirosight LLC. All rights reserved. Verisight Pro + and Envirosight names/logos are trademarks of Envirosight LLC. WinCan is a trademark of CD Lab AG. Information subject to change without notice.

Table of Contents

Save PDF