Download Print this page

Carlisle IntelliSpray IS30 Installation And Quick Start Manual

Spray foam proportioner
Hide thumbs Also See for IntelliSpray IS30:

Advertisement

Quick Links

READ BEFORE INSTALLATION. REFER TO IS30 USERS MANUAL AND QUICKHEAT
HOSE MANUAL FOR COMPLETE INSTALLATION AND USE INSTRUCTIONS.
Maximum Fluid Pressure
Air Pressure Range
Max Fluid Temperature
Wetted Parts
IS30 Quick Start Guide 347493EN Rev A
IntelliSpray™ Spray Foam Proportioner
Installation and Quick Start Guide
SPECIFICATIONS
2500 PSI
(153 bar)
70-130 PSI
(4.8 - 9.0 bar)
200 F
94 C
Stainless Steel, Aluminum, Plated Steel,
Chemically Resistant Plastic, Chemically
Resistant O-Rings
Page 1 of 8
EN
www.carlisleft.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the IntelliSpray IS30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Carlisle IntelliSpray IS30

  • Page 1 IntelliSpray™ Spray Foam Proportioner Installation and Quick Start Guide READ BEFORE INSTALLATION. REFER TO IS30 USERS MANUAL AND QUICKHEAT HOSE MANUAL FOR COMPLETE INSTALLATION AND USE INSTRUCTIONS. SPECIFICATIONS Maximum Fluid Pressure 2500 PSI (153 bar) Air Pressure Range 70-130 PSI (4.8 - 9.0 bar) Max Fluid Temperature 200 F...
  • Page 2 WARNING Read and understand all the warnings in this section and elsewhere in the IS30 User Manual Spray Foam equipment and materials operate under high pressure and temperature and should only be used by trained professionals. The fluids used to create polyurethane foam insulation are hazardous. Unprotected exposure during handling and use may cause lung, ear, and/or skin irration, shortness of breath, sore throat, fever, and even permanent respiratory and/or skin damage and/or sensitization.
  • Page 3: Installation Overview

    Every IS30 is equipped for remote support and can be accessed by authorized Carlisle service agents to assist in system installation, configuration, and/or service.
  • Page 4 INITIAL SYSTEM BLEED When the proportioner and/or hoses are installed, an initial system bleed is required to completely replace air with fluid in the supply hoses, proportioner, and distribution hoses. In addition, if air is introduced to the system (e.g. running the drum pump dry) the same procedure must be performed.
  • Page 5 INITIAL SYSTEM BLEED (Continued) 8. Set B motor speed to 0% by pressing the - button in 11. Press STOP when a steady stream of fluid flows the Motor Speed Widget. from the manifold and all air has been replaced with fluid.
  • Page 6 QUICK-START GUIDE Due to the IS30’s efficient heating systems and simplified startup process, operators will usually be ready to spray within 10-15 minutes from powering on the system. The following are the minimal steps involved in starting up the IS30 with Job Reporting turned off. See the IS30 Users Manual for additional steps required when Job Reporting is turned on.
  • Page 7 QUICK-START GUIDE (Continued) 4. Enter the desired pressure and temperature The center button will change from START to setpoints using the on-screen “+” and “-” buttons. WARMING, and the button boundary will change from solid white to flashing green to indicate the system is warming up.
  • Page 8 NOTES: IS30 Quick Start Guide 347493EN Rev A Page 8 of 8 www.carlisleft.com...