4 Connecting the CAN Bus

4.1 Connection over D-Sub Connector

After the slot bracket has been connected to the CAN interface a CAN bus can be
connected to the D-Sub connector. The pin assignment of the D-Sub connector
corresponds to the specification CiA® 303-1:
10-pin connector
on CAN interface
1
2
3
4
5
8
6, 7, 9, 10

4.2 Cabling

4.2.1 Termination
The High-speed CAN bus (ISO 11898-2) must be terminated with 120 Ω on both ends.
The termination prevents interfering signal reflections and ensures the proper
operation of the transceivers of the connected CAN nodes (CAN interfaces,
control devices).
The CAN interface PCAN-PC/104 Plus Quad does not have an internal termination.
Use the CAN interface on a terminated CAN bus.
4 Connecting the CAN Bus
User Manual 2.0.1
© 2022 PEAK-System Technik GmbH
D-Sub plug on
slot bracket, 9-pin
1
6
2
7
3
9
4, 5, 8
PCAN-PC/104 Plus Quad
Assignment
+5 V (optional)
GND
CAN_Low
CAN_High
GND