Mitsubishi GX50A Operator's Manual page 67

Table of Contents

Advertisement

-2 Check for remaining capacity (battery requiring refilling)
(1) There are two methods of checking the
remaining capacity, measuring the ratio of the
electrolyte and measuring with a battery tester.
(2) When the remaining capacity is low, recharge
immediately.
(3) When the specific gravity ratio of electrolyte is
below 1.220 (20
), recharge it.
Rubber Bulb
Flame Cylinder (Transparent)
Suction Tube
Discharge
Specific
electric
Gravity (20
)
amount (%)
1.280
1.235
1.190
1.145
1.100
(4) Measure using a battery tester and if the range
indicated by the meter is below the yellow
area, recharge it.
Green Area: Normal
Yellow Area: Slightly Discharged
Red Area: Discharged
Hydrometer
Dilute Sulfuric Acid
MN00096_A
Remaining
capacity (%)
0
100
25
75
50
50
75
25
100
0
Battery Tester
MN00095_A
Check of electrolyte (battery requiring refilling)
DANGER
- If the battery is used or charged with
the electrolyte level indicating below the
<LOWER LEVEL> shown on the side of
battery, the battery may explode.
Immediately refill to the level between
the <LOWER LEVEL> and <UPPER
LEVEL>.
(1) The electrolyte level lowers as it is
decomposed by an electric current. When the
electrolyte is insufficient, and the battery plate
is exposed, the service life of the battery is
shortened eminently.
(2) If the electrolyte level is low, recharge the
electrolyte to the <UPPER LEVEL>.
Vent Plug
57
MAINTENANCE
For injury accident prevention
MN00094_A