Mitsubishi GX50A Operator's Manual page 66

Table of Contents

Advertisement

MAINTENANCE
Caution for Setting Battery In/Out
(1) When setting the battery in or out or charging
the battery with a charger, stop the engine,
remove the key and set all the control switches
to OFF.
(2) When removing the battery terminal, remove
the minus terminal on earth side first.
(3) When setting the battery terminal, connect the
plus terminal on plus side first.
Set plus terminal first.
Remove minus
terminal first.
MN00099_A
MN00098_A
56
-1 Check for remaining capacity (battery not requiring refilling)
WARNING
- Do not clean the battery with dry cloth.
It may catch fire and explode due to
static.
- This 12 V battery is exclusive for engine
start. Do not use for other objectives.
- Boost charge is prohibited.
- Do not open. (Battery not requiring
refilling)
(1) Charging status is indicated by the color of
indicator located on the top of the battery.
Refer to the below table for measures.
Color of
Charging
indicator
status
Green
Normal
Black
Discharge
Clear
Low electrolyte
(2) Replace the battery when it is damages and
electrolyte is leaking.
NOTE
- This tractor is provided with a battery not
requiring refilling at the time of shipment.
- Check the indicator from the straight above.
- Electrolyte leakage may cause corrosion of
vehicle.
Measures
Usable
Auxiliary
charge
Replace
Indicator
MN00097_A