Stiga e-PARK 220 Workshop Manual page 70

Table of Contents

Advertisement

WORKSHOP MANUAL
e-PARK 220
c) Battery
The values within the normal operating limits are dis-
played in the table fields.
Exceedances of the normal values is indicated first by the
warning light and then by the warning light with an identifi-
cation code of the fault
INFO
SOC [%]
Battery power reserve status in %
Actual maximum temperature
H TEMP
between sensors in °C
Actual minimal temperature be-
L TEMP
tween sensors in °C
Current value in the cell pack in
CURRENT [A]
amperes from +500 to -50 *
FAULT
Not active
Voltage of the entire cell pack (nor-
VOLTAGE
mal from 37.5 to 59 V)
Maximum voltage of a single cell
H VOLTAGE
in mV
Minimum voltage of a single cell
L VOLTAGE
in mV
= Charging completed and start
BALANCED
of voltage balancing between all
cells
INSULATION
Field not active
* A negative value is displayed during charging.
9 - ELECTRONIC MANAGEMENT - BATTERY
[
9.4.3]
-
[
9.4.4].
SCALE VALUES AND MEANING
BATTERY
CHAPTER
CELL
Field not active
Number of the cell pack area
where it occurs
Number of the cell pack area
where it occurs
Field not active
Field not active
Field not active
Cell number where it occurs
Cell number where it occurs
Cell number where it occurs
Field not active
EDITION
PAGE
2018
70 /
84
c
-
+
= Power reserve
0%
+
= Temperature <
-25°C
+
= Excessive
value
= General alarm for
any cause
Not active
+
= Abnormal
voltage value but the
machine is running
+
= Voltage >3950
mV and machine shut-
down
+
= Abnormal
voltage value but the
machine is running
+
= Voltage <2500
mV and machine shut-
down
+
= Unadjustable
unbalance in one cell
+
= Battery nega-
tive not connected to
the chassis or leakage
in the ground cables