9.5.3 Replacing the ACE-0 control unit

The AC-0 control unit (1) is mounted on a plate (2) and connected to the general electrical system
by means of:
– 1 connector (3);
– 5 screw contacts (4)
marked with embossed
letters on the plastic cover,
to which the ring terminals
corresponding to :
U
= Yellow power cable
+ black shielding
cable;
V
= Blue power cable
+ black shielding
cable;
= Green power cable
W
+ black shielding
cable;
+B = Red power cable +
red cable to the fuse;
–B = Black power cable + 3 black shielding cables from U - V - W.
1. Disconnect all cables and connectors mentioned above.
2. Remove the plate (2) fixed by four screws (5).
When mounting, make sure the connectors and cables are repositioned and tighten the contact
screws (4) to 5.5-6 Nm.