Matco Tools MAXIMUS MDMAX2CSCOPE Instruction Manual
Matco Tools MAXIMUS MDMAX2CSCOPE Instruction Manual

Matco Tools MAXIMUS MDMAX2CSCOPE Instruction Manual

High level 2-channel lab scope with built in multimeter

Advertisement

Version number: V1.00.000
Revised date: 2022-08-30

Advertisement

Table of Contents
loading

Summary of Contents for Matco Tools MAXIMUS MDMAX2CSCOPE

  • Page 1 Version number: V1.00.000 Revised date: 2022-08-30...
  • Page 3 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter WARNING Study, understand and follow all instructions provided with this product. Read these instructions carefully before installing, operating, servicing or repairing this tool. Keep these instructions in a safe, accessible place. Caution: To help prevent personal injury, ...
  • Page 4 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Consultez le manuel du produit pour plus d'informations sur les classifications avant d'effectuer les connexions au produit.  Utilisez une sonde appropriée. Pour éviter tout risque d'électrocution, utilisez une sonde correctement dimensionnée pour votre mesure.
  • Page 5 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter  Mantenga las superficies del producto limpias y secas.  No desmonte ni vuelva a ajustar el dispositivo. El dispositivo es un dispositivo sellado y no hay piezas reparables por el usuario final en su interior. Todas las reparaciones internas deben ser realizadas por agencias de mantenimiento autorizadas o un técnicos autorizados.
  • Page 6 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.
  • Page 7: Table Of Contents

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter CONTENT 1 Overview ............................1 1.1 Product Profile ..........................1 1.2 Accessories Included ........................1 1.3 Technical Parameters ........................2 2 Component and Controls ......................... 4 3 Operations ............................6 3.1 Initial Use .............................
  • Page 9: Overview

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 1 Overview 1.1 Product Profile This MAX2CSCOPE is composed of hardware and software. Hardware includes MAX2CSCOPE module and connection wire. The Oscilloscope and Multimeter APP are installed on diagnostic tool. Automotive oscilloscope can make the auto repair technician to quickly judge the faults on automotive electronic equipment and wiring, and the oscilloscope sweep speed is far greater than the signal frequency of such vehicles, usually 5-10 times of the measured signal.
  • Page 10: Technical Parameters

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Crocodile Clips Designed to connect the bare terminals or leads. Back Probe Pins Suite It can be used to connect sensor and BNC to 4mm Test Leads, and can easily pierce the insulation of wires to allow for automotive electrical measurements without causing damage to the wires.
  • Page 11 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Storage depth 240KB Coupling DC, AC Input impedance 1MΩ±2%, 15pF±5pF parallel Vertical sensitivity 10mV ~ 10V x1 Vertical resolution 8bit Max. input voltage 40V peak value (DC + AC peak value) Probe attenuation coefficient 1X, 10X,100X (need probe support) Trigger type...
  • Page 12: Component And Controls

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 2 Component and Controls Number Name Description Fuse 10A current input port mAμA mA/ 400mA current input port Negative public port V/Ω Voltage/resistance input terminal...
  • Page 13 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter * Note: The ports listed above are measurement ports for multimeter. Handle  Solid Green: Battery level normal  Sold Red: Charging. Power LED  Red Flashes: Battery level low, indicating the battery level is below 20%.
  • Page 14: Operations

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 3 Operations 3.1 Initial Use 3.1.1 Getting Started Tap the Oscilloscope app icon and the following screen will appear: Note: If no proper connection is made, no waveforms will be displayed on the screen and most functions become disabled.
  • Page 15 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter data, oscilloscope settings and Automatic calibration. • About: Displays the detailed information of the app. Trigger It can be used to setup trigger condition and trigger type. Check detailed operation Help instructions of application.
  • Page 16 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Horizontal setting Control the time base. Quick save Quickly saves the measured waveform of current channel. To modify save path and file type, please go into Menu -> Save. Tap this button once, the channel (only the channels that Channel selection button have been turned on) selection...
  • Page 17: Automatic Calibration

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Channel 1 marker Same with “Channel 2 Shows the reference points of the displayed waveforms. marker”. If there is no marker, the channel is not displayed. 3.1.2 Automatic Calibration The automatic calibration routine lets you optimize the oscilloscope signal path for maximum measurement accuracy.
  • Page 18 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter connectors into the Black (GND) and other color (SIGNAL) banana sockets of the 6-way breakout leads (optional) respectively. 2. Connect the black terminal and signal wire (its other end connected to the red 4mm connector) of the 6-way breakout lead to the GND and signal terminal of the vehicle sensor.
  • Page 19: Operations

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 3.2 Operations 3.2.1 Channel Selection A total of 3 channels are available: CH1, CH2 and REF (reference channel). Follow the methods to select a channel: There are two methods for you opt: A.
  • Page 20 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Option descriptions: Menu Comments/Settings This option will affect how channel is displayed. ON: Turn on the invert function. When Invert is set as On, voltage value of displayed wave is reversed (upside down). When using basic trigger, it is Reversed necessary to adjust the trigger level to keep waveform triggered steadily.
  • Page 21: Auto-Set

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter The MAX2CSCOPE applies edge trigger, which is the most commonly used and effective trigger method. A clear majority of applications apply this trigger method to trigger waveform. An edge trigger determines whether the Oscilloscope finds the trigger point on the rising/falling/dual edge of a signal.
  • Page 22: Menu Operations

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter adjusts the vertical and horizontal scaling, as well as the trigger coupling and position. 3.2.4 Menu Operations 1. Measure The MAX2CSCOPE provides 6 parametric auto measurements. Tap Measure, the following screen will appear: Tap to select the desired measurement item.
  • Page 23 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Tap Clear to turn off all measurement items. 2. Save This function allows you to save the waveforms of the channels. Tap Save, the following screen will appear: Select the desired measurement channel and save type (.WAV or .CSV), tap the default file name to revise it.
  • Page 24 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Tap Display, the following screen will appear: 4. User Settings This option can set data clearing, waveform display auto calibration and oscilloscope parameter save and recovery. Tap User Settings, the following screen will appear: Item description: Clear Data: Clear saved data and user setup.
  • Page 25: Car Test Operations

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Displays basic information of the APP. 3.2.5 Car Test Operations This function provides all kinds of the testing applications on the automotive parts (including circuits, sensors, actuators, ignition etc.) and detailed connection methods. Tap Car test, the following screen will appear: Tap to select the desired automotive part, the system will automatically configure the option to the preset parameters.
  • Page 26: Quick Save

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Note: △ Reading: indicates the difference between the two cursor positions. The voltage reading after Y1, Y2: indicates the position of the activated cursor in the horizontal cursor relative to the zero level. The time reading after X1, X2: indicates the position of the activated cursor in the vertical cursor relative to the trigger point.
  • Page 27: Multimeter Operation

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 4. Multimeter Operation Multimeter is mainly used to test voltage, current, resistance, diode and Make-and-break. It only does simple measurements. In this way it can determine if the device is operate normally or fault and if the circuit is complete.
  • Page 28: Current Measurement

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter Numerical mode Displays the measurement result in numerical form. Waveform mode Displays the measurement result in waveform form. Open waveform Open saved waveform file. Save waveform Save measurement result as a waveform file. 5.
  • Page 29: Diode Measurement

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 2. Select Resistance, tap Not connected to search for MAX2CSCOPE. When it is successfully connected, the diagnostic tool will display connection status. 3. Insert black test pen into COM terminal of MAX2CSCOPE, insert red test pen into V/Ω terminal of MAX2CSCOPE.
  • Page 30: Make-And-Break Measurement

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 3. Insert black test pen into COM terminal of MAX2CSCOPE, insert red test pen into V/Ω terminal of MAX2CSCOPE. 4. Attach red test pen to positive end of diode, black test pen to negative end of diode. Keep test pen firmly attached to diode.
  • Page 31: Attention

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter voltage output, replace the knock sensor. Cooling water temperature sensor test (1) Detect coolant temperature sensor resistance Check on the vehicle: Turn off the ignition switch, disconnect the coolant temperature sensor wire connector, and use Resistance to test the resistance between the two terminals of the sensor.
  • Page 32: Care & Maintenance

    MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter 5 Care & Maintenance General Care Do not store or leave the MAX2CSCOPE where the device will be exposed to direct sunlight for long periods of time. Caution To avoid damages to the device or probes, do not expose them to sprays, liquids or solvents. Cleaning Inspect the device and probes as often as operating conditions require.
  • Page 33 MDMAX2CSCOPE High Level 2-Channel Lab Scope with built in Multimeter If you have any questions on the operation of the unit, please contact Matco customer service number: 877-853-3738. Statement: We reserve the rights to change the product design and specifications without prior notice. The appearance and color of the actual product may be different from those shown in the manual.

Table of Contents