4.2.2. Coffee machines

Description
Countertop cutout, download here: https://bit.ly/3xT5TTM
Water mains shutoff valve with a non-return valve (type EA or
according to local regulation)
Descaling cartridge or carbon filter as minimum
Water pressure 2.5 - 4 bars (32.3 - 58 psi) (250 - 400 KPa)
Pressure reducer (only if pressure is above 4 bars)
Flow rate above 140 L/h (Cameo, Légacy)
Water inlet 3/8" (AU and JA G 1/2)
The drain hose must be connected to a siphon (input min. Ø 56
mm (Ø 2.2 in)
Siphon input min. Ø 56 mm (Ø 2.2 in) according to EN 61770
Machine installed with adequate back flow protection to comply
with applicable federal, state or local plumbing codes
Total hardness: 5 - 8° dGH (89-142 ppm)
Carbonate hardness: Max. 6° dKH (107 ppm)
pH value: ideal 7.0 - 7.2
Chlorine (Cl) max. 10 mg/l