Advertisement

Quick Links

Operating Manual
English
CX22B-R

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SOMAT XR CX22B-R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HBM SOMAT XR CX22B-R

  • Page 1 Operating Manual English CX22B-R...
  • Page 2 Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com www.hbm.com Mat.: 7-2002.4722 DVS: A04722_02_E00_00 HBM: public 04.2018 E Hottinger Baldwin Messtechnik GmbH. Subject to modifications. All product descriptions are for general information only. They are not to be understood as a guarantee of quality or...
  • Page 3: Table Of Contents

    ........CX22B-R A04722_02_E00_00 HBM: public...
  • Page 4 ........... . CX22B-R A04722_02_E00_00 HBM: public...
  • Page 5: Safety Instructions

    Please consider following conditions at the place of installation: S Observe the maximum permissible ambient temperatures given in the specifi­ cations. S Minimize device exposure to direct sunlight in hot operating environments. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 6 Maintenance, repair and modification The modules are maintenance-free. Only trained and qualified personnel who are authorized to do so by HBM are allowed to open the module. Before opening the module, disconnect all con­ nections. Operation when open is not allowed. Once the device has been opened, it must be professionally inspected in accordance with EN 60950, before starting it up again.
  • Page 7 - CX22B-R: BR2330A/FAN (soldered) - CX23-R: BR2477 (soldered) Only trained and qualified personnel who are authorized to do so by HBM are allowed to change these batteries. Notice If the module is opened, modified, or inexpertly repaired, the protection pro­...
  • Page 8 With respect to immunity, the standards contain limits for electromagnetically protected (lowest requirements), general and industrial (highest requirements) environments. The SomatXR modules listed in the declaration of conformity conform to the requirements for: - Emissions: Class A - Immunity: Industrial CX22B-R A04722_02_E00_00 HBM: public...
  • Page 9 The supply connection, as well as the signal and sense leads, must be installed in such a way that electromagnetic interference does not adversely affect device functionality. (HBM recommendation: "Greenline shielding design," downloadable from the Internet at http://www.hbm.com/greenline.) The measurement module and devices used in automation equipment must be covered over in such a way that adequate protection or locking against unin­...
  • Page 10 The same also applies to the use of acces­ sories. Maintenance and repair work on an open device with the power on may only be carried out by trained personnel who are aware of the dangers involved. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 11: Markings Used

    Arrows between menu items indicate the sequence in which the menus and sub-menus are called up Data rate Bold text in italics indicates inputs and input fields in the user interfaces. ► Instructions are marked by a small, right-pointing triangle. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 12: Symbols On The Module

    The CE mark enables the manufacturer to guarantee that the product complies with the requirements of the rele­ vant EC directives (the Declaration of Conformity can be found on the HBM support website www.hbm.com. Statutory waste disposal mark see Chapter, Chapter 14.
  • Page 13: Trademarks

    Hottinger Baldwin Messtechnik GmbH. All trademarks and brands used in this document are belonging to the respec­ tive product or the manufacturer/owner. Hottinger Baldwin Messtechnik GmbH does not lay claim to any other than their own trade names/trademarks. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 14: Introduction

    " operating sys­  tem and pre-installed catman Easy software from HBM. Most of the software functionality is described in the data sheet. Interfaces on the back of the Data Recorder: S 2 x FireWire (ODU socket, 4-pin) for connecting SomatXR or QuantumX modules.
  • Page 15: Connections And Displays

    Connections and displays Connections and displays Fig. 4.1 CX22B‒R connections on the front Fig. 4.2 CX22B-R connections on the back CX22B-R A04722_02_E00_00 HBM: public...
  • Page 16: Voltage Supply

    Important The data recorder hosts a small buffer battery. This battery keeps date and time during power interruptions. The battery shall only be replaced by HBM service. Ground connection and grounding Lay the signal and data leads separately from current-carrying power lines. Ca­...
  • Page 17: Connection Of Mx Modules

    - Monitor or touchscreen (DVI) - Mouse and keyboard to USB S Access via a PC or tablet by means of a "remote desktop connection" (stan­ dard in Windows) - Direct connection via an Ethernet patch cable CX22B-R A04722_02_E00_00 HBM: public...
  • Page 18: Usb 2.0 Interfaces

    The level for the outputs is 5 volts (HIGH), when the corresponding output is set, otherwise 0 volts (LOW). The line lengths at the outputs must not exceed 3 m. Maximum output current is 1 mA. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 19: Led Displays

    CX22B‒R (system group), you activate the setting Reset all CX22B‒R digital outputs at the start of a DAQ job. LED displays Fig. 4.3 Position of the LEDs Function Operating condition status POWER = Module LED ERROR LED RUN = RECORDING LED CX22B-R A04722_02_E00_00 HBM: public...
  • Page 20 Connections and displays Fig. 4.4 Pin assignment digital In ‐ and Output CX22B-R A04722_02_E00_00 HBM: public...
  • Page 21 All Status LEDs can also be triggered via Limit values and events in  catman EASY. To do this select Set digital output: CX22B-R digital output in the Configure limit value and event monitoring dialog and enter the re­ quired LED in Bit/Condition . CX22B-R A04722_02_E00_00 HBM: public...
  • Page 22: Connecting Measurement Modules

    CX22B‒R Data Recorder, please update the device firmware. Catman EASY checks the firmware automatically and if necessary, prompts you to update the firmware. The relevant firmware package is supplied with the Data Recorder and is located in the sub-directory C:\Program Files (x86)\HBM\cat­ manEasy_EN\Firmware\QuantumX-B\ CX22B-R A04722_02_E00_00 HBM: public...
  • Page 23 Alternatively, you can connect all MX modules to the CX22B-R via Ethernet. If you have more than two modules you will also require an Ethernet switch. For synchronization an additional FireWire connection or the use of a PTPv2 capa­ ble Ethernet switch (e.g. EX23-R) is required. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 24 Connecting measurement modules DC 10 V ... 30 V X102 X101 Ethernet WLAN DC 10 V ... 30 V Fig. 5.2 Connecting MX modules to the CX22B-R via Ethernet CX22B-R A04722_02_E00_00 HBM: public...
  • Page 25: Operating The Data Recorder

    12 months from the date of delivery. To run an update, you must first register with HBM, in order to benefit from software maintenance. To do this, simply send us the registration file created during initial start-up. This contains the software license number and the device serial number.
  • Page 26: Operation Via A Pc

    For a detailed description, see Section 6.2.2, Page 31 . S The CX22B‒RW Data Recorder is connected via WLAN (the CX22B-R is connected to a hotspot or the PC is connected via the hosted network of the CX22B-R) CX22B-R A04722_02_E00_00 HBM: public...
  • Page 27: A Direct Ethernet Line Between Pc And Data Recorder

    To make it easier to set up a connection when the CX22B‒R settings are un­ known, use the HBM program HBM Device Manager, which is part of the sys­ tem software and included in the package as a DVD. It is also available to download from www.hbm.com.
  • Page 28 ► Select the CX22B‒R from the list. ► In the Change module address, field, enter the required IP address and subnet mask. Example for IP address and subnet mask IP address of the PC: 192.168.0.1/ subnet mask 255.255.255.0. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 29 ► Depending on the configuration of your Windows operating system, another query whether the connection should be set up may be displayed (identity of the remote computer, Fig. 6.3). If necessary, activate the option to pre­ vent the query. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 30 Operating the Data Recorder Fig. 6.3 Identity of the remote computer display The connection to the CX22B‒R Data Recorder will now be established and the login prompt dialog will pop up. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 31: Connection Via A Network

    Please contact your network administrator to obtain the correct settings. ► Install the "HBM Device Manager" program from the system CD. ► Launch the program on your desktop or via the Windows Start menu. ► Click on Find modules.
  • Page 32 ► Select the CX22B‒R once again in the list at the top and then click on Re­ mote connection. For the next steps, please proceed as in the previous Section. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 33: Connection Via Wlan

    ► You can then remove the network cable and use your PC to find the CX22B‒R wireless network and connect to it. ► Now use the HBM Device Manager tool to set up a remote Desktop con­ nection to the CX22B‒R.
  • Page 34: Connection Via A Tablet

    (available as a free download from the Microsoft website). For other operating systems, there are numerous programs for setting up a remote desktop connection to a Windows PC, such as the Remote Desktop for Mobiles RDM+ program for BlackBerry, Android or iPad. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 35: Connection Via Remote Desktop

    Operating the Data Recorder Connection via remote desktop If you do not want to use the HBM Device Manager program or you are work­ ing with a static IP address on the recorder side, you can also set up the con­...
  • Page 36 Enter the IP address of the CX22B‒R and click on Options. S Change the definition used by the HBM Device Manager program. To do this, open the CX22B.rdp file in the installation directory of the HBM Device Manager software.
  • Page 37 Activate data exchange via the clipboard Fig. 6.6 Remote desktop connection local resources tab ► Click on More in the Local resources tab. ► Enable the required drives of your PC for use in the CX22B‒R (Fig. 6.7). CX22B-R A04722_02_E00_00 HBM: public...
  • Page 38 Dialog for enabling additional resources ► Close the dialog. ► Save the configuration via the General tab either under a new name (Save as) or as a default setting for the connection via HBM Device Manager (Save), see Fig. 6.8. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 39: Detecting And Resolving Connection Problems

    Save credentials (see Fig. 6.8), this is done automatically. Detecting and resolving connection problems If the CX22B‒R does not appear in the HBM Device Manager list, or the setup of the remote desktop connection is canceled, there are several possible causes.
  • Page 40 S If your PC has several Ethernet interfaces, try deactivating all the other Eth­ ernet interfaces. S If the HBM Device Manager cannot find the CX22B‒R and you know its IP address or its device name, try settings up the remote desktop connection manually by specifying the IP address or the device name.
  • Page 41: Using Ethernet And Wlan In Parallel

    (1 to 90 seconds) if the used MX modules are also buffered. After  that time, all standard catman actions can take place. In addition it is also   possible to store the data, shut-down catman and to restart catman after the power is back. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 42 Operating the Data Recorder CX22B-R A04722_02_E00_00 HBM: public...
  • Page 43: The Cx22B-R Data Recorder Start Screen

    EASY program. S Change important CX22B‒R settings: Settings. You can use this to change the device name usefull when using remote desktop without the HBM Device Manager and the password, for example,  as well as the language of catman EASY.
  • Page 44 If you have used Exit to Windows to exit the start screen, you can recall it via the CX22Shell (shortcuts on the desktop and in the taskbar). The link brings the start screen to the top. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 45: The First Daq Job With Catman

    ► Define calculations − if required − : Generate in the group Calculation channels. ► Activate Live‐Display (DAQ channels , tab General group), to display continuous measured values and check that all channels are working cor­ rectly. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 46 CX22B‒R measurement mode is activated. If you have defined a start trigger, this will be waited for, if not, measurement will start. The "RUN" LED flashes while waiting for the start trigger and glows continuously as soon as measure­ ment starts. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 47 The device is then set to the characteristic values of this trans­ ducer. In the default setting (condition at the time of delivery) catman uses the English sensor database. But you can switch this to a German or French language database. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 48: Transferring Data/Files To The Pc

    EASY, use the Sensor database context tab and the File menu to load the relevant sensor database from the installation directory "C:\Pro­ gram Files (x86)\HBM\catmanEasy_DE\" or "C:\Program Files (x86)\HBM\catmanEasy_FR\". ► Save this sensor database under a different name to drive D, and open it ...
  • Page 49 In the logon dialog, enter the name of the CX22B‒R, the user name and the password. In the factory settings, the device name is "CX‐serial number" and the user name is HBMCX22. In this case, enter HBMCX22 and the password hbm (Fig. 8.3). CX22B-R A04722_02_E00_00 HBM: public...
  • Page 50: Data Analysis

    EASY/AP, catman Post Process or GlyphWorks from HBM, for example. The recorded file formats can basi­ cally be converted into any other format, such as MAT, ASCII and many others. If binary files (BIN) have been recorded, there are also import filters for programs such as GlyphWorks, FAMOS and others.
  • Page 51: Monitoring Functionality

    SFTP with authentication and data encryption is supported. The FTP upload runs asynchronously in the background so it does not block further DAQ jobs. If a DAQ job contains video captures the video files can also be CX22B-R A04722_02_E00_00 HBM: public...
  • Page 52 - Push‐Notifications Push notifications are short messages which can be sent via the HBM Push Server (a service offered by HBM in the Internet) to any mobile smart device (e.g. iPhone, Android based devices) worldwide. On the mobile device you only need to install the HBM Push App ("HBM Push") which you can download from...
  • Page 53: Configuring The Cx22B-R For Self-Contained Measurements

    EASY loads a DAQ project and launches the DAQ job after startup.  S You must ensure that catman EASY starts when the CX22B‒R is switched As usual, measurement can be started and stopped immediately, or via a trig­ ger. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 54 Important The data already present in the catmanEASY temporary measurement data base are not lost if the power supply is interrupted. This database will be saved according to your job settings (export file name and path). CX22B-R A04722_02_E00_00 HBM: public...
  • Page 55: Saving Data On The Data Recorder

    (UWF, see Section 10.3). In the start screen, click on Maintenance to remove the protection. This way, you will be able to make changes on the C: partition. Do not forget to switch back in Normal mode once you are done with your modifications. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 56: Disk Performance

    CX22B-R is restarted. If you want to permanently make changes to the Windows settings or install new drivers or programs, you first have to switch the CX22B-R into the mainte­ nance mode. (see following chapter). CX22B-R A04722_02_E00_00 HBM: public...
  • Page 57: Maintenance Mode

    CX22B-R has a reliable power supply before switching to the maintenance mode. Note that the CX22B-R is not designed to run measurements in this mode. This mode should only be used temporary to make the necessary changes to the system. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 58 Saving data on the Data Recorder When the modifications to the system are done, you can switch back the CX22B-R into the DAQ mode by clicking on the "Quit maintenance" button in the start screen. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 59: Operating The Cx22B-R As Gateway

    11.2 Activate/deactivate gateway mode To activate/deactivate the gateway mode, go in the Shell settings of the CX22B-R into the "General" tab. Check the option "Activate gateway function­ ality" to activate the option and uncheck it to deactivate it. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 60: Connect To A Quantumx Module Behind A Cx22B-R

    To connect to a QuantumX/SomatXR module being routed by a CX22B-R, look  for this module in the catman's device manager module list. The modules routed by the CX22B-R are displayed as child elements of the CX22B-R. Unlike the CX27, you can select QuantumX/SomatXR modules individually. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 61 Operating the CX22B-R as gateway Important note: You can connect only one time simultaneously to a QuantumX/ SomatXR module being routed by the CX22B-R. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 62: Performances

    CX22B-R: Maximum cumulative data througput (gateway mode) LAN (Gigabit) MS/s > 3 WLAN interface (adhoc) MS/s > 0.2 Test conditions: 12 modules (FireWire), 48 DAQ channels Test conditions: 14 modules (FireWire), 108 DAQ channels CX22B-R A04722_02_E00_00 HBM: public...
  • Page 63: System Settings, Update And Recovery

    CX22B‒R Data Recorder. If additional softwares are installed, the functionality of the CX22B‒R Data Recorder can no longer be guaranteed and HBM can no longer provide support for any error or failure.
  • Page 64: Changing System Settings (Settings)

    Remote Desktop connection.  S Run catman EASY after switching on the CX22B‒R (Launch catman at startup, General tab)  Automatically starts catman EASY as soon as the system is operational. Also see Chapter 9 on Page 53. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 65 CX22B-R. While the update process, the UWF will be disabled and the CX22B-R will be vulnerable to power loss. For that reason, make sure the CX22B-R has a reliable power supply before running the Windows Update. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 66: Updating The Software

    To restore the system, you will need a specially crafted bootable USB flash drive, a keyboard and, where possible, a monitor that you can con­ nect directly to the CX22B‒R (DVI output). Please contact our support site (http://www.hbm.com/support) CX22B-R A04722_02_E00_00 HBM: public...
  • Page 67: Potential Sources Of Error And Remedial Action

    Module decoupled A module or an entire module string may become detached, particularly in the distributed module group, e.g. in trains. You have the option to configure cat­  so that the measurement continues or is canceled. CX22B-R A04722_02_E00_00 HBM: public...
  • Page 68: Fcc (Usa) And Ci (Canada) Statement

    ICES rules, pursuant to part 15, §103 of the FCC rules and ICES-003, chapter 4. Connection of equipment, changes or modifications not expressly authorized by HBM (e.g. by this product manual) may cause additional interference and could void the users authority to operate the CX22B-R.
  • Page 69 Operation of this device in residential areas can cause harmful interferences. In this case the user is obliged clearing off the radio transmission interference at own cost. The European conformity declaration is available on our HBM web­ page: www.hbm.com →...
  • Page 70: Waste Disposal And Environmental Protection

    Packaging The original packaging of HBM devices is made from recyclable material and can be sent for recycling. For ecological reasons, empty packaging should not be returned to us.
  • Page 71: Index

    DHCP, 26 Maintenance, 6 Digital inputs, 18 Maintenance mode, 57 Digital output reset, 19 Markings, 11 Digital outputs, 18 Memory, 48, 55 Module LED, 21 Monitor DVI, digital, 25 ERROR (LED), 21 VGA, 25 Gateway, 59 CX22B-R A04722_02_E00_00 HBM: public...
  • Page 72 Remote Desktop for Mobiles, 34 Repair, 6 Sensor database, 47 Settings, 64 Stand-alone mode, 53 Start screen, 43 Status LED, operating status, 21 Switching off the CX22, 44 Symbols on the module, 12 System restoration, 66 CX22B-R A04722_02_E00_00 HBM: public...
  • Page 73 HBM Test and Measurement Tel. +49 6151 803-0 Fax +49 6151 803-9100 info@hbm.com measure and predict with confidence...