Deviation Of The Airflow Rate On The Am4024(E) - Kontron AM4024 User Manual

Table of Contents

Advertisement

The following table indicates the deviation of the airflow rate on the AM4024(E) module.
Table 40: Deviation of the Airflow Rate on the AM4024(E)
VOLUMETRIC
FLOW RATE [CFM]
5
10
15
20
25
30
35
40
Note:
The AM4024(E) module has an airflow rate deviation of max. ± 5.0% of the average value
of the four thermal zones (max. ± 25% is allowed).
Positive deviation means increased airflow. Negative deviation means decreased airflow.
Note:
The AM4024(E) module provides an open area of 40%. According to the PICMG AMC.0 Spec-
ification, an open area of 20 to 70% perpendicular to the airflow path is recommended.
.
www.kontron.com
PRESSURE DROP [N/m²]
ZONE A
ZONE B
-1.6%
-2.5%
-0.9%
-2.2%
-0.6%
-2.1%
-0.6%
-1.9%
-0.5%
-1.9%
-0.4%
-1.9%
-0.3%
-1.9%
-0.3%
-1.8%
User Guide
AM4024(E)
ZONE C
ZONE D
-0.7%
4.7%
-0.9%
4.0%
-1.2%
3.9%
-1.0%
3.5%
-1.2%
3.6%
-1.2%
3.5%
-1.2%
3.4%
-1.3%
3.3%