5.9 Settings for operation on the Industrial Edge device

Overview of system limits
By default, a BFC Gateway supports up to 60 connected clients (BFC devices).
Up to 50 data points are supported per BFC device, divided into "datasets".
The shortest interval for reading datasets is 200 ms.
Open BFC Gateway ports for incoming communication
Port
Type Protocol
22
TCP
SSH
1883
TCP
MQTT
4840
TCP
OPC UA
8883
TCP
MQTT
9876
TCP
HTTP
9877
TCP
HTTPS
Further setting options are described in the BFCG Function Manual
(https://support.industry.siemens.com/cs/ww/en/view/109801700/).
5.9
Settings for operation on the Industrial Edge device
The Industrial Edge device enables you to install applications including IE Databus, IE Flow
Creator, and IE MQTT Connector.
These apps offer solutions for visualizing data and machine tool-related KPIs which provide
information about the production and machines states.
The Siemens Industrial Edge Hub (https://iehub.eu1.edge.siemens.cloud/) platform also offers
many pre-built apps. For example, the apps "Analyze MyDrives /Edge
(https://support.industry.siemens.com/cs/ww/en/view/109800585)" or "Predictive Service
Analyzer - Converter" were developed for monitoring the drive train.
Settings
Make all necessary configurations for the MQTT connection to Industrial Edge on both sides:
• MQTT settings must be made on the FDE side.
• Insert the certificate and/or user name and password.
• The USS communication must be configured according to the converter and parameters
must be specified manually or via a template (only valid for G120).
The settings and the installation of the Edge applications are described in the Industrial Edge
Management Operating Manual
(https://support.industry.siemens.com/cs/de/en/view/109780393)
46
Use
Encrypted
Commissioning/
Yes
Updates
Commissioning
No
Data forwarding
Yes
Data acquisition
Yes
Commissioning
No
Configuration &
Yes
HTTP REST Client
Description
SSH access for commissioning and system updates
Standard MQTT port for commissioning BFC clients
Standard OPC UA server port.
Used to present collected data.
Standard MQTTS port for data acquisition from BFC clients
HTTP WebUI for commissioning the BFC Gateway
HTTPS WebUI for configuring the BFC Gateway
Operating Instructions, 02/2023, A5E52308942-AB