Pepperl+Fuchs DPU1100 Series Manual

Pepperl+Fuchs DPU1100 Series Manual

Visunet display unit

Advertisement

Quick Links

VisuNet Display Unit
DPU1100-* and DPU1200-*
Manual

Advertisement

Table of Contents
loading

Summary of Contents for Pepperl+Fuchs DPU1100 Series

  • Page 1 VisuNet Display Unit DPU1100-* and DPU1200-* Manual...
  • Page 2 Phone: +49 621 776 - 0 E-mail: info@de.pepperl-fuchs.com North American Headquarters Pepperl+Fuchs Inc. 1600 Enterprise Parkway Twinsburg, Ohio 44087 Phone: +1 330 425-3555 E-mail: sales@us.pepperl-fuchs.com Asia Headquarters Pepperl+Fuchs Pte. Ltd. P+F Building 18 Ayer Rajah Crescent Singapore 139942 Phone: +65 6779-9091 E-mail: sales@sg.pepperl-fuchs.com https://www.pepperl-fuchs.com...
  • Page 3: Table Of Contents

    VisuNet Display Unit Contents Introduction........................ 4 Content of this Document ................4 Target Group, Personnel ................4 Symbols Used ....................5 Product Description ....................6 Overview ......................6 Technical Data 21.5-Inch Model ..............8 Technical Data 19-Inch Model..............10 Marking ......................11 Dimensions and Type Labels..............
  • Page 4: Introduction

    VisuNet Display Unit Introduction Introduction Content of this Document This document contains information that you need in order to use your product throughout the applicable stages of the product life cycle. These can include the following: • Product identification • Delivery, transport, and storage •...
  • Page 5: Symbols Used

    VisuNet Display Unit Introduction Symbols Used This document contains symbols for the identification of warning messages and of informative messages. Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid prop- erty damage.
  • Page 6: Product Description

    Zones 1/21 and 2/22 and Class I/II, Div. 2, and Class III. Connected to a Pepperl+Fuchs thin client or PC unit, the DPU serves as a display with an optional touch screen. It enables users to perceive the system outputs of the computing unit and to input user data.
  • Page 7 VisuNet Display Unit Product Description Figure 2.2...
  • Page 8: Technical Data 21.5-Inch Model

    5 capacitive front keys (behind glass): 1 home button, 2 brightness control buttons, 1 touchscreen button, 1 power button Interface Interface type Interface v1.0 from Pepperl+Fuchs for com- puting units from Pepperl+Fuchs Bluetooth® v4.0, communication distance up to 30 m in open terrain Ambient conditions Operating temperature 0 ...
  • Page 9 VisuNet Display Unit Product Description Mechanical specifications Degree of protection IP66 (when mounted on the TCU or PCU unit from Pepperl+Fuchs) Material Surface Front: glass (optional with stainless steel bezel) Back: Powder-coated aluminum Mass approx. 15 kg (DPU1100-*) approx. 11 kg (DPU1200-*)
  • Page 10: Technical Data 19-Inch Model

    5 capacitive front keys (behind glass): 1 home button, 2 brightness control buttons, 1 touchscreen button, 1 power button Interface Interface type Interface v1.0 from Pepperl+Fuchs for com- puting units from Pepperl+Fuchs Bluetooth® v4.0, communication distance up to 30 m in open terrain Ambient conditions Operating temperature -20 ...
  • Page 11: Marking

    499 mm x 419 mm Marking ATEX / IECEx / UKEx Marking Display Unit DPU1100-J1-* Pepperl+Fuchs Group Lilienthalstraße 200, 68307 Mannheim, Germany ATEX: II 2G Ex eb q ib IIC T4 IP66 Gb II 2D Ex tb IIIC T80 °C Db IECEx: IECEx BVS 16.0061X...
  • Page 12 VisuNet Display Unit Product Description UL Marking Note FCC Digital Devices Statement for All DPU Models This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 13: Dimensions And Type Labels

    VisuNet Display Unit Product Description Dimensions and Type Labels Dimensions 21.5-Inch Model Figure 2.3 Dimensions with bezel 21.5 inch ø 6.5 (20x) Figure 2.4 Hole pattern 21.5 inch Note The VisuNet GXP DPUs can be mounted within the AG-XX00 housing as well as panel mounted or flush mounted.
  • Page 14 VisuNet Display Unit Product Description Dimensions 19-Inch Model Figure 2.5 Dimensions with bezel 19 inch 129.5 129.5 Figure 2.6 Hole pattern 19 inch Note The VisuNet GXP DPUs can be mounted within the AG1 housing as well as panel mounted or flush mounted.
  • Page 15 VisuNet Display Unit Product Description Labels The following labels are present on the display unit. Type label display unit optional: GXP type label optional, in case of a GXP panel, otherwise mounted on GXP enclosure Warning marking "Warning – Do not open! This enclosure is fac- tory sealed."...
  • Page 16: Installation

    The use of the device is only permitted under the ambient conditions (temperature, humidity, vibration and shock) which are specified in the technical data. Failure to comply with any of these conditions void the warranty for the device. Pepperl+Fuchs cannot be held liable for any damage arising from improper use and handling.
  • Page 17: Mechanical Installation

    Mounting the PCU/TCU onto the DPU Ensure the correct position of the PCU/TCU. Place the PCU/TCU with the Pepperl+Fuchs connector above the Pepperl+Fuchs socket on the back of the display unit. Carefully push the Pepperl+Fuchs connector into the Pepperl+Fuchs socket.
  • Page 18: Repair

    Carefully align the PCU/TCU with the DPU when connecting the units. Mounting or dismount- ing the PCU/TCU at an angle can damage the pins. Repair Note The DPU can be dismounted from the PCU/TCU and sent to Pepperl+Fuchs for repair and/or replacement. For mounting and dismounting instructions, see the VisuNet GXP system manual.
  • Page 19: Operation And Configuration

    VisuNet Display Unit Operation and configuration Operation and configuration Front buttons The DPU1100-*/DPU1200-* provides several system functions via the capacitive front buttons. The front buttons are embedded in the system and located behind the security glass. Warning! Warning! Do not use sharp tools like screwdrivers to trigger the front buttons. Warning! Warning! Do not use the display when there are scratches in the front glass.
  • Page 20 VisuNet Display Unit Operation and configuration Power ON - on (solid on (solid on (flashing on (solid on (solid Display OFF white) white) white) white) green) (brightness 0 %) Sleeping on (flashing mode green) Status OFF - Power OFF LEDs off Status OFF - Power ON Power LED solid white Power ON - Touch screen ON...
  • Page 21 VisuNet Display Unit Operation and configuration Power ON - Display OFF (brightness 0 %) • Power LED solid green • "Brightness +" LED flashing white • Other LEDs solid white Sleeping • Power LED flashing green • Other LEDs off Brightness control The service controller sets the backlight brightness and controls it directly with the two bright- ness buttons.
  • Page 22 In this way the exact finger/stylus position can be located on the touch screen. Note Pepperl+Fuchs' capacitive touch screens have been tested for use with gloves. For a list of tested gloves, see chapter 6.3. Touch Sensitivity To increase or decrease the sensitivity of the touch screen, several different sensitivity profiles are available.
  • Page 23 VisuNet Display Unit Operation and configuration Locking / Unlocking front buttons The capacitive front buttons are sensitive to water and moisture. To avoid "false positive" button triggers in challenging environments, the front buttons can be protected with a lock mechanism in Service Controller firmware versions 1.3.2.198 and higher.
  • Page 24 VisuNet Display Unit Operation and configuration Unlocking the front buttons via VisuNet RM Shell 5 In the enabled keypad lock mechanism, none of the front buttons operates individually, but the front buttons continue to show the same state as unlocked. The attempt to press a key causes all LEDs to flash 3 times.
  • Page 25: Bluetooth Interface

    VisuNet Display Unit Bluetooth Interface Bluetooth Interface Pepperl+Fuchs' DPU1100/DPU1200 series display units are available with an optional Blue- tooth® interface. This enables Bluetooth devices (i.e., an Ident-Ex® 01 handheld scanner) to be used with VisuNet HMI systems. For the Bluetooth interface to work properly, you must disable a Windows® setting that allows the computer to automatically turn off Bluetooth.
  • Page 26: Appendix

    With current LCD technology, a panel may contain a limited number of missing or flickering pix- els. Pepperl+Fuchs display units are tested according to internationally recognized standards in order to fulfill the tolerated pixel errors. The following pixel errors in the LC display are due to production and do not represent an rea-...
  • Page 27 VisuNet Display Unit Appendix Temperature Error (too Low) Indication Problem Solution "Brightness -" button solid Temperature too low (moni- Check if ambient temperature white tored only during booting up) surrounding the panel is lower Power button solid red than the panel's allowed oper- ating temperature.
  • Page 28: Gloves Tested For Touch Sensitivity

    Appendix Gloves Tested for Touch Sensitivity This section lists selected gloves and their touch sensitivity with the capacitive touch screen. This test was conducted by Pepperl+Fuchs. Warning! Warning! It is the end-user's responsibility to choose appropriate gloves. The below list is not exhaustive, and it only deals with touch sensitivity.
  • Page 29: Chemical Resistance Of Sealant And Gasket

    The display unit consists of a chemically edged front glass and an optional stainless steel bezel. The chemical resistance of the sealant between the glass and bezel was specified by the sealant manufacturer. Pepperl+Fuchs also tested the resistance of the sealant and the resistance of the gasket between the bezel and the housing.
  • Page 30 XX=good resistance, X=medium resistance, 0=non or only short-term resistance Chemical Resistance as Determined by Pepperl+Fuchs Pepperl+Fuchs tested the chemical resistance of the sealant and gasket to selected chemicals. When submerged in the following chemicals for 48 hours at an ambient temperature of 25 °C, the sealant remained undamaged.
  • Page 31 Pepperl+Fuchs Quality Download our latest policy here: www.pepperl-fuchs.com/quality www.pepperl-fuchs.com © Pepperl+Fuchs · Subject to modifications / DOCT-5356G...