I/O Configuration Parameter Writing - Ebyte K62-DL20 User Manual

0/4 20ma analog transmission module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Example: The network disconnection recovery time is set to: 30 seconds. After the sender and receiver are
disconnected, the product will continue to search for connections. If the connection between the sender and the
receiver is still disconnected after 30 seconds, the product network indicator "NET" light is off, and the receiver
returns to the default output parameter of 0mA.
(3) Refresh interval: Refers to the time interval for synchronous refresh of the data of the sender and the
receiver. Note: The refresh interval is related to the parameters related to the communication mode, see Table
4-3 below.
Refresh interval: comparison with the parameters related to the communication method
way of communication
LoRa
LoRa
LoRa
LoRa
LoRa
(4) Channel value: the channel value of the acquisition (or sender).
Channel properties
Current type
(default)
Voltage type (can
be customized)

4.3.3 I/O configuration parameter writing

(1) Refer to "
I/O configuration Refer to
following
parameter
(2) I/O configuration parameter writing:
1. Example: Write 4~20mA file, 60s disconnection recovery time, 2s refresh interval.
2. Steps (as shown in Figure 4-12): Select the correct COM port number and correct (default) parameters →
click "Open Serial Port" (if the parameters have been changed and forgotten, they can be restored to factory settings)
→ "Search/Read Device" → "I/O configuration" → pull down to select " 4 ~ 20mA " → input network
disconnection recovery time 60s (0s, 30~57600s) → pull down to select the desired refresh interval time 2s →
click "write" in "3.I/O configuration" Enter " → the log column prompts success → According to Table 4-2,
configure the LoRa wireless airspeed to 2.4Kbps → click "Write" in "2.LoRa Configuration" → log column
prompts success → click "Save" → read next Check whether the verification is successful → click "Restart"
→ Repeat "
I/O Configuration " Parameter reading and parameter description
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
30
57600 seconds (default
30 seconds)
Table 4-2 Refresh interval and communication mode parameter comparison table
Refresh time (seconds)
0.2
0.5
1 (default)
2
5
Value range
0~20mA
0~10V
Table 4-2 for each parameter and parameter description, and enter the
writing steps.
seconds
to
the disconnection time is exceeded, the receiving
end outputs 0mA.
Parameters that need to be
changed accordingly
≥4.8Kbps (airspeed)
2.4Kbps (airspeed)
0~5V
Enable disconnection recovery. That is, after
The communication method
is wireless spread spectrum
technology. Users should
conduct experiments
according to the environment
and finally determine a
relatively stable parameter.
illustrate
Send and receive channel analog current input
detection value
Send and receive channel analog voltage input
detection value
" chapter steps to check.
K62-DL20 User Manual
illustrate
37