1.4 Internal circuit structure diagram of the product
1.4.1The internal principle diagram of the transmitter (collection) end product
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Flashing for 0.5 seconds: indicates that the product is in normal operation;
RUN
After 3 seconds of steady light, recovery will flash for 0.5 seconds: long
press the button for 3 seconds, it means the factory reset is successful.
Steady on: The second communication interface is connected successfully;
NET
Off: The second communication interface is disconnected.
Blinking: Indicates that the product sends out a data signal.
TXD
Blinking: Indicates that the product has received a data signal.
RXD
Always on: output 0/4~20mA signal;
AO1
Off: 0/4~20mA signal is not output.
Always on: output 0/4~20mA signal;
AO2
Off: 0/4~20mA signal is not output.
Always on: output 0/4~20mA signal;
AO3
Off: 0/4~20mA signal is not output.
Always on: output 0/4~20mA signal;
AO4
Off: 0/4~20mA signal is not output.