Chengdu Ebyte Electronic Technology Co.,Ltd.
Port and
serial
Other
number
Definitions
1
PE
2
+
3
-
4
B/RX
5
A/TX
6
G
second
7
communicat
ion interface
8
AI1
9
GND
10
AI2
11
GND
12
AI3
13
GND
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Figure 1-3 Display of the transmitter (collection) end product interface
Table 1.3.2 Pin Function Definition of Transmitter (Acquisition) End Products
Function
protective earth
terminal
Positive power
supply
power ground
Communication
interface B/RXD
Communication
interface A/TXD
communication port
Antenna
port/network port
Analog input 1
channel
input negative
Analog input 2
channels
input negative
Analog input 3
channels
input negative
Lightning protection grounding. If the ground lead is good, it is
recommended to connect the product casing to the ground;
otherwise, it is OK.
The power input is positive, and the DC input voltage range is 8-28V.
Power input negative (0V).
485 interface B/(RS232_RXD).
485 interface A/(RS232_TXD).
485 ground (can not be connected) / RS232 signal ground (0V).
433Mhz antenna port/network port socket
0/4~20mA analog signal input channel 1.
Input negative (0V).
0/4~20mA analog signal input channel 2.
Input negative (0V).
0/4~20mA analog signal input channel 3.
Input negative (0V).