Indicator Light Description - Ebyte K62-DL20 User Manual

0/4 20ma analog transmission module
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
on interface
8
AO1
9
GND
10
AO2
11
GND
12
AO3
13
GND
14
AO4
15
GND
16
17
SFR
18
SIM

1.3.3 Indicator light description

(1) LED light indication on the transmitting (collecting) end, as shown.
Copyright ©2012–2021,Chengdu Ebyte Electronic Technology Co.,Ltd.
Analog input 1
0/4~20mA analog signal output channel 1.
channel
input negative
Input negative (0V).
Analog input 2
0/4~20mA analog signal output channel 2.
channels
input negative
Input negative (0V).
Analog input 3
0/4~20mA analog signal output channel 3.
channels
input negative
Input negative (0V).
Analog input 4
0/4~20mA analog signal output channel 4.
channels
input negative
Input negative (0V).
without
Leave it in the air, do not connect.
Press and hold for 3 seconds to restore the factory settings (Set
reset
Factory Reset) (indicated by the status of the RUN light).
SIM card slot
Insert a data IoT card and a phone card with a data plan.
Table 1-5 Function table of analog input module
Figure 1-5