Terminal Block; Connecting Or Disconnecting Accessories; Battery Backup (Optional For Smart & Secure) - B&D Smart Pro SDO-9V3 Installation Instructions Manual

Sectional door opener
Table of Contents

Advertisement

Smart Pro, Smart & Secure installation instructions

14.2 Terminal Block

Wired accessory items can be connected to the terminal block J4.
Terminal connections from top down are as follows:
a. +35V (Auxillary)
b. AUX (Auxillary)
c. SB (Safety Beam input, mandatory);
d. GND (Common ground for accessories and Safety Beam);
e. GND (Common ground)
f. OSC (Open/Stop/Close trigger)

14.3 Connecting or Disconnecting Accessories

The opener can hold up to 4 accessories. For example Secure;
• Auto-Lock
• Wireless PE Beams
• Smart Hub
If an Auto-lock and Wireless PE Beams are both installed
tip
ensure that the channels on the base stations on each
device are different. The channel on the base station
can be changed by sliding the switch in either direction
C O N N E C T O R D I S C O N N E C T A C C E S S O R I E S
S T E P O N E
Remove controls cover
Press
till gear
repeatedly
LED lit
S T E P T H R E E
For PE Beams
Alignment Mode is
entered.
Ensure Alignment.
Re-registering is required every time an accessory is removed.
14.4 Battery Backup (Optional for Smart & Secure)
When installed, Battery backup keeps the opener functional
when mains power is turned off, however note the following;
i. Phone app (if installed) operation will depend on the
availability of Wi-Fi connectivity
ii. Limit setup is not available when running from batteries.
iii. Battery backup will not be activated if the PG3 has
connected to the opener 60 secs prior to mains power
being turned off. This is to allow a reboot to take place
without having to shutdown battery backup.
iv. Battery backup will not be activasted if a fault is active
prior to mains power being tunred off. This allows opener
power to be cycled to reset fault.
B A T T E R Y B A C K U P
B A T T E R Y S H U T D O W N
When under battery power
To manually
shutdown
opener
HOLD for 10 secs
S T E P T W O
till
HOLD for 2 secs
3 beeps
are heard
OFF
Then replace controls cover
T E S T B A T T E R Y
When under mains power
till
HOLD for 4 secs
beep
15