Technical Specifications; Power Supply Specifications; Copper Ethernet Port Specifications - Siemens SIMATIC NET RUGGEDCOM RMC40 Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

Technical Specifications

This section provides important technical specifications related to the device and
available modules.
4.1

Power Supply Specifications

a
(T) denotes time-delay fuse.
b
This is the same power supply for both AC and DC.
4.2

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered
with the RUGGEDCOM RMC40.
Speed
Connector
Duplex
Cable Type
Wiring Standard
Maximum Distance
Isolation
a
Auto-negotiating.
b
Shielded or unshielded.
c
Auto-crossover and auto-polarity.
d
Typical distance. Dependent on the number of connectors and splices.
e
RMS 1 minute.
RUGGEDCOM RMC40
Installation Manual, 11/2022, C79000-G8976-1009-10
Power
Minimum Input
Supply Type
24 VDC
18 VDC
48 VDC
36 VDC
b
HI
88 VDC
85 VAC
a
10/100Base-TX
RJ45
a
FDX/HDX
b
> CAT-5
c
TIA/EIA T568A/B
d
100 m (328 ft)
e
1.5 kV
Maximum Input
Internal
Fuse Rating
36 VDC
3.15A (T)
59 VDC
300 VDC
264 VAC
4
Max. Power
a
Consumption
5 W
17