New Volumes Detected; Too Many Volumes Detected - HP StorageWorks MSA500 G2 User Manual

Table of Contents

Advertisement

2. Remove and reinstall all SCSI drives, and be sure that they seat fully in their
bays.
3. Check for proper connections on the cables to and from the MSA500 G2
storage system.
4. Power up the storage system (on page 27).
If this action does not solve the problem, contact HP support.

122 New Volumes Detected

Type: Informational
Description: Configured volumes from another controller were migrated to this
controller. The controller updated the configuration information.
Action: None

123 Too Many Volumes Detected

Type: Error
Description: The controller detected more than 32 volumes (maximum
supported) at power up. This condition can occur when the ACU migrates a set
of volumes from one controller to a different controller that already contains
configured volumes. The controller does not add the migrated volumes.
Action:
1. Remove the migrated drives.
2. Run ACU.
3. Delete any unneeded volumes until the number of existing volumes plus the
number of volumes awaiting migration is equal to or less than 32 volumes.
4. Add the migrated volumes.
If this action does not solve the problem, contact HP support.