Array Controller Temperature Ok; Array Controller Overheating; Array Controller Overheated - HP StorageWorks MSA500 G2 User Manual

Table of Contents

Advertisement

201 Array Controller Temperature OK

Type: Informational
Description: The controller temperature is within the normal operating range.
This message appears when the temperature problem no longer exists, and it
follows message 202 and/or message 203.
Action: None

202 Array Controller Overheating

Type: Error
Description: The temperature sensor on the controller indicates the controller is
exceeding the normal operating range.
Action:
1. Be sure that all MSA500 G2 storage system fans are operating.
2. Replace any failed fans.
3. Be sure that all bays are populated with components or blanks.
If this action does not solve the problem, contact HP support.

203 Array Controller Overheated

Type: Error
Description: The temperature sensor on the controller indicates the controller
exceeded the normal operating range.
Action:
1. Avoid hardware failure. Power down the storage system (on page 28).
2. Be sure that all MSA500 G2 storage system fans are operating.
3. Replace any failed fans.
Troubleshooting
119

Advertisement

Table of Contents
loading

Table of Contents