108 Volume #<n> State Missing Drives
Type: Error
Description: The configured volume is unusable because too many drives that
constitute the volume are missing. The controller will disable this volume.
Action:
1. Power down the storage system (on page 28).
2. Power down all attached storage enclosures.
3. Remove and reinstall all SCSI drives, and be sure that they seat fully in their
bays.
4. Check for proper connections on the cables to and from the MSA500 G2
storage system.
5. Power up the attached storage enclosures.
6. Power up the storage system (on page 27).
If this action does not solve the problem, contact HP support.
109 Volume #<n> State Wrong Drive Replaced
Type: Error
Description: The controller recognizes drive replacement on working physical
drives rather than failed drives.
Action:
1. Power down the storage system (on page 28).
2. Reinstall the working drives.
3. Replace the failed drives.